2017
DOI: 10.1016/j.bios.2017.05.007
|View full text |Cite
|
Sign up to set email alerts
|

A novel label-free electrochemical immunosensor based on the enhanced catalytic currents of oxygen reduction by AuAg hollow nanocrystals for detecting carbohydrate antigen 199

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0
1

Year Published

2018
2018
2022
2022

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 48 publications
(13 citation statements)
references
References 57 publications
0
12
0
1
Order By: Relevance
“…The limit of detection (LOD, S/N = 3) was calculated to be 0.4 U/mL CA 19-9. As listed in Table S2, a lower LOD was obtained in the developed method compared with that of the reported methods, including photothermal immunoassay (0.83 U/mL), immuno-chromatographic (5.0 U/mL), and CL immunoassay (2 U/mL), and slightly higher with that of the previously reported methods including label-free electrochemical immunosensors with the enhanced catalytic currents (0.23 U/mL, 50 μL) and commercial ELISA kit (0.1 U/mL, 50 μL), but these two methods need large volume of target/sample. Importantly, the LOD obtained is much lower than the cutoff value of 37 U/mL CA 19-9 for diagnosis of pancreatic cancer, which has 69% sensitivity and 85% specificity .…”
Section: Results and Discussionmentioning
confidence: 75%
“…The limit of detection (LOD, S/N = 3) was calculated to be 0.4 U/mL CA 19-9. As listed in Table S2, a lower LOD was obtained in the developed method compared with that of the reported methods, including photothermal immunoassay (0.83 U/mL), immuno-chromatographic (5.0 U/mL), and CL immunoassay (2 U/mL), and slightly higher with that of the previously reported methods including label-free electrochemical immunosensors with the enhanced catalytic currents (0.23 U/mL, 50 μL) and commercial ELISA kit (0.1 U/mL, 50 μL), but these two methods need large volume of target/sample. Importantly, the LOD obtained is much lower than the cutoff value of 37 U/mL CA 19-9 for diagnosis of pancreatic cancer, which has 69% sensitivity and 85% specificity .…”
Section: Results and Discussionmentioning
confidence: 75%
“…152,153 To date, researchers have developed a variety of HMNM-based electrochemical, FL and colorimetric biosensors to detect disease-related protein markers, such as tumor, hepatic, cardiac, inflammatory markers, and others (Table 2). 24,30,35,36,46,47,49–52,64,65,81,84,85,88,89,98,101–103,107–110,114,122,154–178…”
Section: Applications Of Hmnms In Analytical Chemistrymentioning
confidence: 99%
“…11 Advanced nanomaterials have a significant role in the development of electrochemical immunosensors. 12 In this regard, wrinkled fibrous nano-silica (WFNS) have attracted the attention of electrochemical immunoassay devices. 13 WFNS nanomaterials have been noted for their easy synthesis, adjustable particle size, large pore volume, excellent mechanical stability, low toxicity, complete biocompatibility, adjustable pore size, and unique large surfaces.…”
Section: Introductionmentioning
confidence: 99%
“…Advanced nanomaterials have a significant role in the development of electrochemical immunosensors 12 . In this regard, wrinkled fibrous nano‐silica (WFNS) have attracted the attention of electrochemical immunoassay devices 13 .…”
Section: Introductionmentioning