2009
DOI: 10.1016/j.bios.2008.06.053
|View full text |Cite
|
Sign up to set email alerts
|

A novel hydrogen peroxide sensor based on the direct electron transfer of horseradish peroxidase immobilized on silica–hydroxyapatite hybrid film

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
32
0
1

Year Published

2010
2010
2022
2022

Publication Types

Select...
7
3

Relationship

0
10

Authors

Journals

citations
Cited by 143 publications
(38 citation statements)
references
References 40 publications
1
32
0
1
Order By: Relevance
“…Therefore, several calcium orthophosphate-based biocomposites and hybrid biomaterials were found to be applicable for biosensor manufacturing. 354,642,1041,1083,[1122][1123][1124][1125][1126][1127] For example, formation of poly-l-lysine/HA/carbon nanotube hybrid nanodimensional particles was described, and a general design strategy for an immunosensing platform was proposed based on adsorption of antibodies onto this biocomposite. 1083 In another paper, a hybrid material formed by assembling nanodimensional particles of gold onto nano-sized HA was employed for the interface design of a piezoelectric immunosensor on which the antibodies were bound.…”
Section: ©2 0 1 1 L a N D E S B I O S C I E N C E D O N O T D I S Tmentioning
confidence: 99%
“…Therefore, several calcium orthophosphate-based biocomposites and hybrid biomaterials were found to be applicable for biosensor manufacturing. 354,642,1041,1083,[1122][1123][1124][1125][1126][1127] For example, formation of poly-l-lysine/HA/carbon nanotube hybrid nanodimensional particles was described, and a general design strategy for an immunosensing platform was proposed based on adsorption of antibodies onto this biocomposite. 1083 In another paper, a hybrid material formed by assembling nanodimensional particles of gold onto nano-sized HA was employed for the interface design of a piezoelectric immunosensor on which the antibodies were bound.…”
Section: ©2 0 1 1 L a N D E S B I O S C I E N C E D O N O T D I S Tmentioning
confidence: 99%
“…Figure 4 presents the Nyquist plots of the impedance spectroscopy of the bare and modified ITO electrodes in the frequency range of 10 À1 to 10 4 Hz. The diameter of the semicircle for CH deposited ITO electrode (curve b) is much larger than the bare ITO electrode (curve a), suggesting that the CH film formed on the surface of ITO hinders the electron transfer between the redox probe of [Fe(CN) 6 ] 3À / 4À and the electrode surface. When the GFe 3 O 4 composites were embedded in CH to modified ITO electrode, the diameter decreased markedly (curve c).…”
Section: Electrochemical Studies Of the Biosensormentioning
confidence: 95%
“…As far as we know, the lower detection limit is better than those of other DET-type HRP enzyme electrodes based on CNTs [13][14][15] and other materials. 28,29 Compared to bare Pt electrode, which exhibits potential detection at +0.60 V (vs. Ag | AgCl), this electrode seems to be able to detect the lower concentrations of hydrogen peroxide. However, a Pt electrode needs a variety of surface modifications for selective detection of hydrogen peroxide as described above.…”
Section: Hrp/cnts/gc Electrodes For Hydrogen Peroxide Detectionmentioning
confidence: 99%