A novel hydrogen peroxide biosensor based on horseradish peroxidase immobilized on gold nanoparticles–silk fibroin modified glassy carbon electrode and direct electrochemistry of horseradish peroxidase

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
60
0
1

Year Published

2010
2010
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 137 publications
(65 citation statements)
references
References 47 publications
4
60
0
1
Order By: Relevance
“…3C inset, the anodic or cathodic peak current was proportional to the scan rate, as I pa ( A) = 1.0488 + 113.7v(V s −1 ) (R = 0.9987) and I pc ( A) =−1.0063 − 113.84v(V s −1 )( R = 0.9984). This further suggested the electrochemical behaviour of HRP on the NAEs was typical of a surface-controlled quasi-reversible process (Yin et al, 2009), verifying that immobilized HRP was stable on the NAEs.…”
Section: Direct Electron Transfer Of Hrp On the Gold Nanowire Array Ementioning
confidence: 72%
See 2 more Smart Citations
“…3C inset, the anodic or cathodic peak current was proportional to the scan rate, as I pa ( A) = 1.0488 + 113.7v(V s −1 ) (R = 0.9987) and I pc ( A) =−1.0063 − 113.84v(V s −1 )( R = 0.9984). This further suggested the electrochemical behaviour of HRP on the NAEs was typical of a surface-controlled quasi-reversible process (Yin et al, 2009), verifying that immobilized HRP was stable on the NAEs.…”
Section: Direct Electron Transfer Of Hrp On the Gold Nanowire Array Ementioning
confidence: 72%
“…The K app M values of HRP/NAE 2h , HRP/NAE 4h and HRP/NAE 5h were 1.87, 1.54 and 0.64 mM, respectively, significantly lower than reported values in Table 2. These results indicated that the immobilized HRP possessed high enzymatic activity and the HRP/NAEs exhibited high affinity for H 2 O 2 (Yin et al, 2009).…”
Section: Electrocatalytic Reduction Of H 2 Omentioning
confidence: 79%
See 1 more Smart Citation
“…4, inset), a detection limit of 0.003 mM was estimated at the signal-to-noise ratio of 3. The modified electrode displays a wider linear range and lower detection limit than those reported in literature [21]. The excellent electrocatalytic activity of the electrode toward H 2 O 2 also means that the electrode can represent a new electrochemical platform that provides operational access to a large number of oxidase-based enzymes for fabricating bienzyme biosensors.…”
Section: Electrocatalysis Of Cyt C/gnps/pans/gc Electrodementioning
confidence: 89%
“…As far as we know, the lower detection limit is better than those of other DET-type HRP enzyme electrodes based on CNTs [13][14][15] and other materials. 28,29 Compared to bare Pt electrode, which exhibits potential detection at +0.60 V (vs. Ag | AgCl), this electrode seems to be able to detect the lower concentrations of hydrogen peroxide. However, a Pt electrode needs a variety of surface modifications for selective detection of hydrogen peroxide as described above.…”
Section: Hrp/cnts/gc Electrodes For Hydrogen Peroxide Detectionmentioning
confidence: 99%