2012 International Conference on Multimedia Computing and Systems 2012
DOI: 10.1109/icmcs.2012.6320189
|View full text |Cite
|
Sign up to set email alerts
|

A novel fixed-switching-frequency DTC for PMSM drive with low torque and flux ripple based on Sinusoidal Pulse With Modulation and predictive controller

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0

Year Published

2014
2014
2019
2019

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(10 citation statements)
references
References 15 publications
0
10
0
Order By: Relevance
“…This technique is presented in Figure 10.b can be called symmetrical SVM. It's seen that this technique is to alternate the null vector in each sequence and reverse the sequence after each null vector, all that in each modulation period T m [7,20]. However, with this sequence strategy the 3 legs inverter are in commutation which generates 8 switching states in each T m .…”
Section: Space Vector Modulationmentioning
confidence: 99%
See 1 more Smart Citation
“…This technique is presented in Figure 10.b can be called symmetrical SVM. It's seen that this technique is to alternate the null vector in each sequence and reverse the sequence after each null vector, all that in each modulation period T m [7,20]. However, with this sequence strategy the 3 legs inverter are in commutation which generates 8 switching states in each T m .…”
Section: Space Vector Modulationmentioning
confidence: 99%
“…However, for some applications, the DTC has become unusable although it significantly improves the dynamic performance (fast torque and flux responses) of the drive and is less dependent on the motor parameters variations compared to the classical vector control (FOC) due to torque and flux ripples [7]- [8]. Indeed, hysteresis controllers used in the conventional structure of the DTC generates a variable switching frequency, causing electromagnetic torque oscillations.…”
Section: Introductionmentioning
confidence: 99%
“…Output voltage of VSI can be framed by equation (4). Where Va, V b and V c are the output voltage of VSI and V DC is the input DC voltage.…”
Section: B Modelling Of Voltage Source Invertermentioning
confidence: 99%
“…DTC has simple calculation and no coordinate transformations. It only requires knowledge of stator resistance, which reduces the machine parameter dependency [3][4][5][6][7][8]. But basic DTC has some disadvantages; switching frequency of inverter varies with error band speed of the motor [9].…”
Section: Introductionmentioning
confidence: 99%
“…Most of the past research on DTFC based motor drives mainly concentrated on the development of the inverter control algorithms with less torque ripple as it is the major drawback of DTFC [1][2][3][4][5][6][7][8][9][10][11][12][13][14]. In DTFC scheme the motor actual torque and air gap flux linkage values are compared with their corresponding reference values.…”
Section: Introductionmentioning
confidence: 99%