2018
DOI: 10.1016/j.snb.2017.08.134
|View full text |Cite
|
Sign up to set email alerts
|

A novel ferrocenyl-based multichannel probe for colorimetric detection of Cu(II) and reversible fluorescent “turn-on” recognition of Hg(II) in aqueous environment and living cells

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
7
0
1

Year Published

2018
2018
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 40 publications
(9 citation statements)
references
References 68 publications
1
7
0
1
Order By: Relevance
“…30 However, the LOD calculated in this work is a value that is in the same order of magnitude compared with other chemosensors recently reported in the literature. 3133 In order to determine the stoichiometry of the complex, the Job’s plot study of the fluorescence emission for 3b –Hg 2+ interaction was made. This curve showed a maximum around 0.3 indicating the formation of complex 3b :Hg 2+ with a molar ratio that can be between 2:1 and 3:1 (Figure 6).…”
Section: Results and Discussionmentioning
confidence: 99%
“…30 However, the LOD calculated in this work is a value that is in the same order of magnitude compared with other chemosensors recently reported in the literature. 3133 In order to determine the stoichiometry of the complex, the Job’s plot study of the fluorescence emission for 3b –Hg 2+ interaction was made. This curve showed a maximum around 0.3 indicating the formation of complex 3b :Hg 2+ with a molar ratio that can be between 2:1 and 3:1 (Figure 6).…”
Section: Results and Discussionmentioning
confidence: 99%
“…The interesting fact about all these ferrocene‐based ions recognition systems is that upon complexation with metal cations or hydrogen bond formation with anions, they undergo significant perturbations of the ferrocene/ferrocenium redox couple. The values of the corresponding anodic or cathodic oxidation potential shifts provide information about the strength of the recognition event …”
Section: Applications Of Ferrocene‐based Electro and Photo Responsivementioning
confidence: 99%
“…It is well known that Hg 2+ is harmful to human health and environment because it can cause deadly damages to organs of the human body including the brain, nervous system, endocrine system, and kidneys. , Therefore, it is necessary to develop some rapid and efficient methods to identify Hg 2+ .…”
Section: Introductionmentioning
confidence: 99%