2016
DOI: 10.1016/j.jdiacomp.2015.12.005
|View full text |Cite
|
Sign up to set email alerts
|

A novel device for accurate and efficient testing for vision-threatening diabetic retinopathy

Abstract: Aims To evaluate the performance of the RETeval device, a handheld instrument using flicker electroretinography (ERG) and pupillography on undilated subjects with diabetes, to detect vision-threatening diabetic retinopathy (VTDR). Methods Performance was measured using a cross-sectional, single armed, non-interventional, multi-site study with Early Treatment Diabetic Retinopathy Study 7-standard field, stereo, color fundus photography as the gold standard. The 468 subjects were randomized to a calibration ph… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

4
75
1

Year Published

2016
2016
2019
2019

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 61 publications
(86 citation statements)
references
References 42 publications
4
75
1
Order By: Relevance
“…used the RET eval device to screen for DR, and reported that it detected vision-threatening DR, e.g., severe NPDR or PDR, with a high level of sensitivity (AUC, 0.86)24. Their findings and the value of the AUC are comparable to our results.…”
Section: Discussionsupporting
confidence: 84%
See 3 more Smart Citations
“…used the RET eval device to screen for DR, and reported that it detected vision-threatening DR, e.g., severe NPDR or PDR, with a high level of sensitivity (AUC, 0.86)24. Their findings and the value of the AUC are comparable to our results.…”
Section: Discussionsupporting
confidence: 84%
“…The details of the RET eval (LKC Technologies, Gaithersburg, MD) device, a small, hand-held, non-mydriatic full-field flicker ERG recording system, have been described in detail22232425. The full-field flash stimuli are presented with a small dome of 60 mm in diameter (Fig.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The RETeval™ (LKC Technologies, Inc., Gaithersburg, MD, USA) is a handheld device for recording the full-field electroretinogram (ERG), which aims to improve the ease of ERG recording in a general clinical or office environment [13]. Equipped with a small Ganzfeld dome, an infrared LED and camera system (for monitoring the subject’s eye) and skin electrodes, it is designed to record monocular ERGs.…”
Section: Introductionmentioning