2018
DOI: 10.1007/s10008-018-3906-2
|View full text |Cite
|
Sign up to set email alerts
|

A novel carbon/chitosan paste electrode for electrochemical detection of normetanephrine in the urine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
7
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(7 citation statements)
references
References 43 publications
0
7
0
Order By: Relevance
“…In order to evaluate whether the electron transfer process of ETB at the composite modified electrode is diffusion or adsorption controlled, cyclic voltammetry was employed in the range of 10-500 mV s -1 , Figure 3. The result showed that the peak current for 50 µM ETB in 0.1 M PBS pH 7 linearly increases with the square root of scan rates in the range of 10-500 mV s -1 with the linear regression equation of I p (µA) = 5.5 (±0.1) v 1/2 (mV s -1 ) 1/2 + -2.8 (±1.5), R 2 = 0.9943, Inset of Figure 3.This relationship suggests that the electrochemical reaction of ethambutol at the NiNPs/ERGO modified electrode is mainly diffusion-controlled electrode process [22][23][24][25][26]. The relationship between the logarithm of the peak current and the logarithm of the scan rate (log I p vs log v) is also linear with the regression equation of log I p (µA) = 0.56 (±0.02) log v (mV s -1 ) + 0.60 (±0.03), R² = 0.9903.…”
Section: Effect Of Potential Scan Ratementioning
confidence: 84%
“…In order to evaluate whether the electron transfer process of ETB at the composite modified electrode is diffusion or adsorption controlled, cyclic voltammetry was employed in the range of 10-500 mV s -1 , Figure 3. The result showed that the peak current for 50 µM ETB in 0.1 M PBS pH 7 linearly increases with the square root of scan rates in the range of 10-500 mV s -1 with the linear regression equation of I p (µA) = 5.5 (±0.1) v 1/2 (mV s -1 ) 1/2 + -2.8 (±1.5), R 2 = 0.9943, Inset of Figure 3.This relationship suggests that the electrochemical reaction of ethambutol at the NiNPs/ERGO modified electrode is mainly diffusion-controlled electrode process [22][23][24][25][26]. The relationship between the logarithm of the peak current and the logarithm of the scan rate (log I p vs log v) is also linear with the regression equation of log I p (µA) = 0.56 (±0.02) log v (mV s -1 ) + 0.60 (±0.03), R² = 0.9903.…”
Section: Effect Of Potential Scan Ratementioning
confidence: 84%
“…However, electrochemical methods were primarily identified for catecholamine metabolites. One interesting example is the multiplexed detection of catecholamines and their metabolites (El Khamlichi et al., 2018; Zaytsev et al., 2020). Khamlichi et al.…”
Section: Tailored Biosensing Strategiesmentioning
confidence: 99%
“…Khamlichi et al. used a carbon/chitosan paste electrode for multiplex normetanephrine and dopamine electrochemical detection in five‐fold diluted human urine with LODs of 18.3 and 7.6 ppb, respectively (El Khamlichi et al., 2018). Zaytsev et al .…”
Section: Tailored Biosensing Strategiesmentioning
confidence: 99%
“…Due to the advantages of a high surface area, sustainability, good conductivity, and chemical stability, porous carbon materials (PCs) have shown great potential for applications in many fields in recent year [12][13][14]. The synthetic strategies and the structures of their precursors significantly affect the final performance and application of porous carbons [15,16].…”
Section: Introductionmentioning