2009
DOI: 10.1016/j.aca.2009.03.045
|View full text |Cite
|
Sign up to set email alerts
|

A novel biosensor based on photoelectro-synergistic catalysis for flow-injection analysis system/amperometric detection of organophosphorous pesticides

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
16
1

Year Published

2010
2010
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 40 publications
(18 citation statements)
references
References 25 publications
0
16
1
Order By: Relevance
“…Recently, starting from 2009, a very interesting approach was also proposed, based on photoelectrochemical detection through photoactive electrodes, such as PbO 2 /TiO 2 /Ti (Wei et al, 2009), bismuth oxyiodide flake array (Gong et al, 2012) and nitrogen and fluorine co-doped TiO 2 nanotubes (Huang et al, 2013). In presence of irradiation, electrons can be excited and move to the conduction band, leaving holes in the valence band.…”
Section: Enzymes Employed In Biosensors Based On Enzyme Inhibitionmentioning
confidence: 98%
“…Recently, starting from 2009, a very interesting approach was also proposed, based on photoelectrochemical detection through photoactive electrodes, such as PbO 2 /TiO 2 /Ti (Wei et al, 2009), bismuth oxyiodide flake array (Gong et al, 2012) and nitrogen and fluorine co-doped TiO 2 nanotubes (Huang et al, 2013). In presence of irradiation, electrons can be excited and move to the conduction band, leaving holes in the valence band.…”
Section: Enzymes Employed In Biosensors Based On Enzyme Inhibitionmentioning
confidence: 98%
“…The kinetic effect of the photo-excited electrode material (poly-hematoxylin) was exploited for a faster NADH oxidation compared to the electrochemical process. A similar strategy was exploited in a biosensor for organophosphorus pesticides, with performance evaluated for trichlorfon [188].…”
Section: Kinetic-based Applicationsmentioning
confidence: 99%
“…Many efforts have been made to develop sensitive, convenient and effective methods for OP residues analysis in environmental and other samples [1,2]. Gas chromatography (GC) [3,4], GC-Mass Spectrometry (MS) [5], and high performance liquid chromatography (HPLC)-MS [6–8] are commonly used methods to successfully detect OP residues in practical samples with high selectivity, sufficient sensitivity and precision.…”
Section: Introductionmentioning
confidence: 99%