A Novel Active Interphase Transformer Scheme to Achieve Three-Phase Line Current Balance for 24-Pulse Converter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 36 publications
(10 citation statements)
references
References 9 publications
0
10
0
Order By: Relevance
“…In [8] and [17], twelve 3 L-NPC PEBBs are combined too, but using six Inter-Phase Transformers (IPTs) [18]. In [17], the output transformer is connected in open-end configuration and the VA rating of the intermediate magnetic elements that are needed to combine the PEBBs is reduced compared to the topology presented in [8].…”
Section: Ip-zsbt Magnetic Configuration For Parallelization-serializamentioning
confidence: 99%
See 1 more Smart Citation
“…In [8] and [17], twelve 3 L-NPC PEBBs are combined too, but using six Inter-Phase Transformers (IPTs) [18]. In [17], the output transformer is connected in open-end configuration and the VA rating of the intermediate magnetic elements that are needed to combine the PEBBs is reduced compared to the topology presented in [8].…”
Section: Ip-zsbt Magnetic Configuration For Parallelization-serializamentioning
confidence: 99%
“…The IPTs allow to connect converters in parallel and increase the converter output power [27].By using the IPT, the current is equally shared between the parallelized legs [8]. Fig.…”
Section: Inter-phase Transformermentioning
confidence: 99%
“…However, with the increasing number of output windings in a phase-shift transformer, the phase-shifting transformer structure becomes complicated and the utilization ratio of turn coils is depressed, causing difficulties in design and manufacture. Because the 12-pulser rectifier is the simplest and the most popular MPR, several circuit topologies with active or passive auxiliary circuits are proposed to install at the dc or ac side of 12-pulse rectifier, which can effectively lower the input line current harmonics [12][13][14][15][16][17][18][19][20][21][22]. The harmonic reduction at the 2 of 18 dc-side is carried out by injecting current through an interphase reactor (IPR) [12].…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, researchers have explored a variety of methods to reduce the input line current distortion of diode recti ers in recent decades . Compared with other harmonic reduction methods, because of the small kilo-Volt Ampere (kVA) rating of auxiliary current injection circuit and excellent harmonic reduction ability, the method of active harmonic reduction at dc side is suitable for high power applications and has drawn more and more attention [16][17][18][19][20][21][22][23][24][25][26].…”
Section: Introductionmentioning
confidence: 99%
“…The proposed AIPT scheme consists of three IPTs and a current-controlled inverter with rating required to be only 1.16% of the system power rating. In [21], a double-star diode recti er with an auxiliary PWM recti er is also presented. It draws near sinusoidal utility line currents with less than 5% THD.…”
Section: Introductionmentioning
confidence: 99%