1994
DOI: 10.1016/0021-9290(94)90283-6
|View full text |Cite
|
Sign up to set email alerts
|

A note on some identification problems arising in roentgen stereo photogrammetric analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2000
2000
2013
2013

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 23 publications
(8 citation statements)
references
References 5 publications
0
8
0
Order By: Relevance
“…These cages are based on the same laboratory system, but cage 77 is modified to allow better visualization of cage markers when the cage is attached to film‐switchers. Marker scattering and stability was documented using the condition number (CN) and the mean error of rigid body fitting (ME) . In the evaluation of abduction, the median (range) CN varied between 43 (35–46), 49 (20–150), and 79 (23–90) for the femoral, acetabular, and cup markers, respectively.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…These cages are based on the same laboratory system, but cage 77 is modified to allow better visualization of cage markers when the cage is attached to film‐switchers. Marker scattering and stability was documented using the condition number (CN) and the mean error of rigid body fitting (ME) . In the evaluation of abduction, the median (range) CN varied between 43 (35–46), 49 (20–150), and 79 (23–90) for the femoral, acetabular, and cup markers, respectively.…”
Section: Methodsmentioning
confidence: 99%
“…Marker scattering and stability was documented using the condition number (CN) 10 and the mean error of rigid body fitting (ME). 11,12 In the evaluation of abduction, the median (range) CN varied between 43 (35-46), 49 (20-150), and 79 (23-90) for the femoral, acetabular, and cup markers, respectively. The corresponding median (range) mean errors (ME) were 0.08 (0.07-0.20), 0.24 (0.11-0.34), and 0.23 (0.14-0.33).…”
Section: Cemented Total Hip Replacementsmentioning
confidence: 99%
“…The RSA method has been continuously developed to improve its applicability in different fields of orthopaedic research (Kärrholm 1989, Söderqvist and Wedin 1993, Nyström et al 1994, Börlin 1997, Kärrhohn et al 1997, and Vrooman et al 1998. During the late twentieth century manual measurements of RSA radiographs were gradually replaced by digital measurements.…”
Section: Control Pointsmentioning
confidence: 99%
“…These techniques are mostly based on the direct linear transformation (DLT) algorithm [1], optimized [18] or modified [2,4,6,11,12,21,22], making it possible to reconstruct a point using its projections on two X-ray films. Although quite accurate on the vertebral body of non-pathological vertebrae, these techniques are far from being optimal on scoliotic vertebrae [3,20], because of the lack of identifiable stereo-corresponding points in certain vertebral regions, e.g., the posterior arch.…”
Section: A Mitulescu W Skalli D Mitton J a De Guisementioning
confidence: 99%