1989
DOI: 10.1016/0168-9002(89)90802-4
|View full text |Cite
|
Sign up to set email alerts
|

A new tomographic device based on the detection of fluorescent x-rays

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
53
0

Year Published

1998
1998
2018
2018

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 120 publications
(54 citation statements)
references
References 7 publications
1
53
0
Order By: Relevance
“…The detector model was based on a commercially available cadmium-telluride (CdTe) gamma and x-ray detector (XR-100T-CdTe, Amptek, Inc.), which had a beryllium window of 100 µm thickness, 1.27 mm behind which was a 3 × 3 × 1 mm 3 CdTe crystal serving as the active area of the detector. The detector housing, comprised of the head and base of the detector, was also modeled.…”
Section: A3 Cadmium-telluride X-ray Detector and Collimationmentioning
confidence: 99%
See 1 more Smart Citation
“…The detector model was based on a commercially available cadmium-telluride (CdTe) gamma and x-ray detector (XR-100T-CdTe, Amptek, Inc.), which had a beryllium window of 100 µm thickness, 1.27 mm behind which was a 3 × 3 × 1 mm 3 CdTe crystal serving as the active area of the detector. The detector housing, comprised of the head and base of the detector, was also modeled.…”
Section: A3 Cadmium-telluride X-ray Detector and Collimationmentioning
confidence: 99%
“…In recent years, a traditionally synchrotron based technique known as x-ray fluorescence computed tomography (XFCT) [1][2][3][4] has emerged as a valuable quantitative imaging tool which can be used to determine the biodistribution of high-Z metal probes such as iodine, gadolinium, platinum, and gold. While monochromatic x-rays are considered ideal 5 for XFCT, the impracticality of using synchrotrons in typical biomedical laboratory settings, especially for in vivo imaging of small animals, has motivated the implementation of XFCT on a benchtop setting using a polychromatic diagnostic energy-range x-ray source (viz., "benchtop XFCT").…”
Section: Introductionmentioning
confidence: 99%
“…Then, fluorescent x-ray scanning tomography was developed in order to investigate spatial distributions of specific elements. Fluorescent x-ray scanning tomography employing an x-ray tube has been used to study iodine in samples of several millimeters in diameter (Cesareo & Mascarenhas, 1989), while x-ray fluorescence scanning microtomography employing synchrotron radiation has been used in studies of Fe and Ti in 8-mm samples and in the detection of iron in a bee head (Boisseau & Grodzins, 1987). However, 2-dimensionally scanning a sample is time-consuming.…”
Section: Sr-fxct Based On Pencil Beam Geometrymentioning
confidence: 99%
“…The ®rst uorescent tomogram using X-ray tubes demonstrated a 0.5% iodine solution in a volume of 2.5 Â 2.6 Â 2.5 mm (Cesareo & Mascarenhas, 1989), and micro-tomography with synchrotron radiation showed iron in the head of a bee (Boisseau & Grodzins, 1987). In Japan,¯uorescent tomography with synchrotron radiation has been performed since 1993, and can detect about 200 ng of iodine in a 4 mm 3 volume (Takeda, Ito et al, 1994;Takeda, Maeda et al, 1995.…”
Section: Fluorescent X-ray Ctmentioning
confidence: 99%