2019
DOI: 10.1016/j.saa.2019.02.071
|View full text |Cite
|
Sign up to set email alerts
|

A new sensitive approach for spectrofluorimetric assay of Milnacipran and Amisulpride in real plasma and pharmaceutical preparations via complexation with Eosin Y dye

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 12 publications
(9 citation statements)
references
References 14 publications
0
8
0
Order By: Relevance
“…Therefore, eosin Y was applied to determine several pharmaceutical compounds using spectrophotometric, [ 11,26,27 ] spectrofluorimetric, [ 28–30 ] or both spectrophotometric and spectrofluorimetric [ 31–33 ] methods by forming either binary or ternary complexes. Due to binary complex formation of eosin Y with CFX, a quenching effect was produced on the native fluorescence of eosin Y at λ ex.…”
Section: Resultsmentioning
confidence: 99%
“…Therefore, eosin Y was applied to determine several pharmaceutical compounds using spectrophotometric, [ 11,26,27 ] spectrofluorimetric, [ 28–30 ] or both spectrophotometric and spectrofluorimetric [ 31–33 ] methods by forming either binary or ternary complexes. Due to binary complex formation of eosin Y with CFX, a quenching effect was produced on the native fluorescence of eosin Y at λ ex.…”
Section: Resultsmentioning
confidence: 99%
“…The chemical structure of milnacipran hydrochloride (MCN). Several analytical assays were described for the detection of MCN in dosage forms and in biological fluids such as spectrophotomety (4-14) (Table 1), spectrofluorimetry (15,16), high-performance liquid chromatography (HPLC) (17)(18)(19)(20)(21)(22)(23)(24), high-performance Thin layer chromatography (HPTLC) (25)(26)(27). Most of the reported procedures for the determination of MCN suffer from the use of complex instruments, the need high expertise in their use, in Utilization of ion-pair complexation reaction for the spectrophotometric determination of milnacipran HCl as anti-depression drug in pharmaceutical formulations addition the unavailability of these instruments in several quality control laboratories.…”
Section: Hclmentioning
confidence: 99%
“…High concentration of dyeing wastewater discharge way has caused a series of problems such as soil saline–alkalization (Xia et al., 2018). Eosin Y has been widely used as a textile and art dye, and now it is very popular in detection field for many pharmaceutical preparations (Atia, Marzouq, Hassan, & Eltoukhi, 2019). Eosin Y enters the environment through human activities, and it is not only very toxic to aquatic organisms, but also threatens human health (Goswami & Das, 2019).…”
Section: Introductionmentioning
confidence: 99%