2022
DOI: 10.1016/j.microc.2022.107947
|View full text |Cite
|
Sign up to set email alerts
|

A new ratiometric fluorescent detection of Glucose-6-phosphate dehydrogenase enzyme based on dually emitting carbon dots and silver nanoparticles

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 35 publications
0
4
0
Order By: Relevance
“…The corresponding linear range of G6PD was 0.1 to 1.0 × 10 4 U/L (Figure S7A,B) and the limit of detection was 0.03 U/L ( S / N = 3), which was significantly better than the results of previous reports (Table S3). In addition, the PEC method for G6PD was relatively simple to operate compared to the fluorescent, , colorimetric, , and electrochemical methods that usually involve multi-step reactions. The photocurrent responses from some potential interferents were obtained to evaluate the selectivity of the assay (Figures D and S7C).…”
Section: Results and Discussionmentioning
confidence: 99%
“…The corresponding linear range of G6PD was 0.1 to 1.0 × 10 4 U/L (Figure S7A,B) and the limit of detection was 0.03 U/L ( S / N = 3), which was significantly better than the results of previous reports (Table S3). In addition, the PEC method for G6PD was relatively simple to operate compared to the fluorescent, , colorimetric, , and electrochemical methods that usually involve multi-step reactions. The photocurrent responses from some potential interferents were obtained to evaluate the selectivity of the assay (Figures D and S7C).…”
Section: Results and Discussionmentioning
confidence: 99%
“…The dual emission strategy is a versatile and effective approach that capitalizes on the intrinsic fluorescence properties of CDs. In this method, CDs are engineered or modified to emit light at two distinct wavelengths under the excitation of a single wavelength [ 64 , 66 , 67 , 74 , 98 , 99 , 100 , 101 , 102 , 103 , 104 , 105 , 106 , 107 ] ( Figure 4 ). These dual-emitting CDs offer a built-in reference signal, enhancing the accuracy and reliability of ratiometric measurements.…”
Section: Construction Strategies Of Cds In Detecting Environmental Co...mentioning
confidence: 99%
“…One of these emissions typically serves as the analyte-specific response signal, while the other serves as a constant reference signal. The reference signal remains unaffected by environmental changes, making it an ideal internal standard for calibration and quality control [ 64 , 67 , 103 , 104 , 105 , 106 , 107 ].…”
Section: Construction Strategies Of Cds In Detecting Environmental Co...mentioning
confidence: 99%
See 1 more Smart Citation
“…Typically, researchers can perform both bioluminescence and fluorescence imaging without the assistance of staff with special expertise. There are many advantages to fluorescence imaging, including high-throughput screening for compound optimization, high sensitivity, and multi-color imaging, as well as its shortcomings, including lack of clinical translation and low-depth penetration [144,149,150]. Using fluorescence imaging techniques with polymeric nanoparticles, researchers could monitor drug pharmacokinetics and drug delivery [151].…”
Section: Fluorescence Imagingmentioning
confidence: 99%