2004
DOI: 10.1002/elan.200302789
|View full text |Cite
|
Sign up to set email alerts
|

A New Procedure for Voltammetric Lead Determination Based on Coprecipitation and Centrifugation Preconcentration

Abstract: An arrangement of a voltammetric cell specially designed to be compatible to both centrifugation and voltammetry was designed, allowing direct measurement without any need for dissolution or filtration steps. The procedure for the preconcentration via coprecipitation is described. The system was succesfully tested using trace amounts of Pb(II) ions in aqueous solution preconcentrated with Al(OH) 3 as the carrier precipitate and resulting peak currents were found much higher than those without applying centrifu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
30
0

Year Published

2009
2009
2021
2021

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 20 publications
(31 citation statements)
references
References 8 publications
(4 reference statements)
1
30
0
Order By: Relevance
“…Up to this amount, the increase in current can be attributed to more carrier material will carry more analyte onto the electrode surface. Meanwhile, the decrease in the current value might be due to the polylayer formation of carrier material onto the electrode surface which rendered the oxidation process of FA that was trapped into these layers [29,30].…”
Section: Optimization Of 4ncà No 2 Amountmentioning
confidence: 99%
See 2 more Smart Citations
“…Up to this amount, the increase in current can be attributed to more carrier material will carry more analyte onto the electrode surface. Meanwhile, the decrease in the current value might be due to the polylayer formation of carrier material onto the electrode surface which rendered the oxidation process of FA that was trapped into these layers [29,30].…”
Section: Optimization Of 4ncà No 2 Amountmentioning
confidence: 99%
“…By applying centrifuga-tion, the analyte is deposited onto the electrode surface and without engaging any separation techniques, the analyte's redox behaviour is monitored voltammetrically [28]. Up to now, metallic substances [29,30] together with biologically important analytes [31,32,33,34,35] were detected by this method. Also, the electrode was modified with suitable enzymes [36,37] or cell lines [38] and various biocentri-voltammetric methods were developed.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…At this point, it is not possible to state the exact reason but these two explanations seem reasonable to us. On the other hand, current decrease at the higher speeds might be due to destruction of analyte layer that was on the electrode surface [30][31][32]36,38,39 . All optimization of centrifugal parameters experiments were performed in presence of 5.0x10 -5 M DA in 6.7x10 -2 M pH:7 PBS.…”
Section: Optimization Of Experiments Conditionsmentioning
confidence: 99%
“…The effects of different amount of SDS on the sensor response for 5Optimization of centrifugal parameters: The centrifugation parameters are very important in centri-voltammetry[30][31][32][33][34][35][36][37][38][39] . In this study, SDS molecules should be deposited onto electrode surface in order to obtain electrostatic interaction with DA.…”
mentioning
confidence: 99%