1999
DOI: 10.1143/jjap.38.38
|View full text |Cite
|
Sign up to set email alerts
|

A New Method for the Precise Measurement of Wafer Roll off of Silicon Polished Wafer

Abstract: A new method using a stylus profiler and a block gauge has been developed to measure the precise profile of wafer roll off occurred within the edge exclusion length. The results from the new method have a good agreement of those using the conventional capacitive gauging tool, when the height deviation of wafer roll off is measured. The new method can specify the exact lateral position with respect to the physical edge of wafer.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
3
0

Year Published

2007
2007
2020
2020

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 28 publications
(6 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…Before the experiments, the surface of the polishing pad was conditioned with a #170 diamond disc. The obtained edge roll-off was quantitatively evaluated by the roll-off amount (ROA), which is defined as the vertical displacement from the level line to the measured wafer profile at a position 1 mm from the wafer edge [10]. The level line was at 3-6 mm from the edge.…”
Section: Polishing Pad Properties Determining Edge Roll-offmentioning
confidence: 99%
“…Before the experiments, the surface of the polishing pad was conditioned with a #170 diamond disc. The obtained edge roll-off was quantitatively evaluated by the roll-off amount (ROA), which is defined as the vertical displacement from the level line to the measured wafer profile at a position 1 mm from the wafer edge [10]. The level line was at 3-6 mm from the edge.…”
Section: Polishing Pad Properties Determining Edge Roll-offmentioning
confidence: 99%
“…2. 9) The measurement point is generally located 1 mm from the outermost periphery of the wafer. The reference line is generally a straight line fitting the surface profile at 3 to 6 mm from the outermost periphery of the wafer.…”
Section: Wafer Edge Roll-offmentioning
confidence: 99%
“…ROA is defined as the vertical height distance from the leveled surface to the profile in the roll off region at the position 1 mm distant from the physical edge. The leveled surface is set to be the approximate line on 3 mm -6 mm from the physical edge [6]. As for the edge shape, ROA in Pad A was smaller than that in Pad B (Fig.…”
Section: Investigation Of the Influence Of Polishing Pressure On Edge...mentioning
confidence: 99%