2010
DOI: 10.1016/j.gaitpost.2010.04.012
|View full text |Cite
|
Sign up to set email alerts
|

A new method for synchronization of motion capture and plantar pressure data

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
3
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
5
3
1

Relationship

0
9

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 3 publications
0
3
0
Order By: Relevance
“…Up to now, the anatomical masking approach has been applied to a prototype pressure platform and dedicated integration software by the Italian National Institute of Health together with a five-segment foot model by Istituti Ortopedici Rizzoli (Giacomozzi C et al, 2000;Stebbins JA et al, 2005), and to Novel platforms and dedicated integration software together with the Oxford Foot Model . A further methodological study based on a Tekscan platform (Miller AL, 2010) only dealt with reference system integration issues.…”
Section: Regional Parameters: Potentialities Of Different Methodologimentioning
confidence: 99%
“…Up to now, the anatomical masking approach has been applied to a prototype pressure platform and dedicated integration software by the Italian National Institute of Health together with a five-segment foot model by Istituti Ortopedici Rizzoli (Giacomozzi C et al, 2000;Stebbins JA et al, 2005), and to Novel platforms and dedicated integration software together with the Oxford Foot Model . A further methodological study based on a Tekscan platform (Miller AL, 2010) only dealt with reference system integration issues.…”
Section: Regional Parameters: Potentialities Of Different Methodologimentioning
confidence: 99%
“…Data were collected for nine foot segments: medial heel (MH), lateral heel (LH), midfoot (MF), metatarsals 1-5 (M1-5), and hallux. For each foot segment, the following data were obtained: contact area [cm 2 ], maximum force [%BW], and peak pressure [kPa] [15].…”
Section: Plantar Pressure Variablesmentioning
confidence: 99%
“…Up to now, the anatomical masking approach has been applied to a prototype pressure platform and dedicated integration software by the Italian National Institute of Health together with a five-segment foot model by Istituti Ortopedici Rizzoli (Giacomozzi C et al, 2000;Stebbins JA et al, 2005), and to Novel platforms and dedicated integration software together with the Oxford Foot Model (Giacomozzi C et al, 2010). A further methodological study based on a Tekscan platform (Miller AL, 2010) only dealt with reference system integration issues.…”
Section: Regional Parameters: Potentialities Of Different Methodologi...mentioning
confidence: 99%