2000
DOI: 10.1016/s0168-1656(99)00237-0
|View full text |Cite
|
Sign up to set email alerts
|

A new method for on-line measurement of the volumetric oxygen uptake rate in membrane aerated animal cell cultures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
32
0

Year Published

2001
2001
2022
2022

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 65 publications
(33 citation statements)
references
References 25 publications
1
32
0
Order By: Relevance
“…This value is within the range of reported SOUR values for CHO cell cultures between 0.25 and 0.29 pmol cell À1 h À1 (Ducommun et al, 2000) and 0.35 pmol cell À1 h À1 (Mostafa and Gu, 2003). This result also indicates that Equation (14) is applicable in the CHO cell culture process…”
supporting
confidence: 86%
See 1 more Smart Citation
“…This value is within the range of reported SOUR values for CHO cell cultures between 0.25 and 0.29 pmol cell À1 h À1 (Ducommun et al, 2000) and 0.35 pmol cell À1 h À1 (Mostafa and Gu, 2003). This result also indicates that Equation (14) is applicable in the CHO cell culture process…”
supporting
confidence: 86%
“…P T is the pressure at the sparger (mmHg), and y O 2 and y CO 2 are the molar fraction of oxygen and carbon dioxide in the inlet gas sparge flow, respectively. The Henry coefficient H O 2 and H CO 2 (atm l mol À1 ) under ambient pressure are adapted from the empirical equations in literature (Ducommun et al, 2000;Spérandio and Paul, 1997) …”
Section: Dynamic Determination Of the Oxygen Transfer Coefficientmentioning
confidence: 99%
“…The bioreactor was operated in batch or continuous (perfusion) mode at a temperature of 37°C, agitation (marine turbine) of 150 rpm with bubble-free aeration controlled by the use of 1-2 m Teflon tubing (W. L. Gore & Associates GmbH, Putzbrunn, Germany). Using a recently developed regulation system (Ruffieux et al 1998;Ducommun et al 2000), the dissolved oxygen concentration, determined using a polarographic oxygen electrode, (Ingold, Messtechnik AG, Urdorf, Switzerland) was maintained at 80% air saturation while simultaneously enabling the on-line measurement of the specific oxygen consumption rate. The pH was maintained constant at a value of 7.2 by the automatic addition of CO 2 to the inlet airflow.…”
Section: Cell Culturesmentioning
confidence: 99%
“…The state of the art in in vivo techniques that use wound oxygenation level as an indirect tool to assess wound healing include the use of polarographic probe or needle electrode on subcutaneous wound tissues for surface measurement of partial oxygen (PO 2 ) level, 9 and the use of luminescence lifetime imaging (LII) 10 for two dimensional visualization of PO 2 based on the quenching of phosphorescence. Even though photoacoustic imaging is a noninvasive technique to provide blood vessel mapping, it requires a long operation time.…”
Section: Introductionmentioning
confidence: 99%