A new measuring and identification approach for time-varying bioimpedance using multisine electrical impedance spectroscopy

Abstract: The bioimpedance measurement/identification of time-varying biological systems Z(ω, t) by means of electrical impedance spectroscopy (EIS) is still a challenge today. This paper presents a novel measurement and identification approach, the so-called parametric-in-time approach, valid for time-varying (bio-)impedance systems with a (quasi) periodic character. The technique is based on multisine EIS. Contrary to the widely used nonparametric-in-time strategy, the (bio-)impedance Z(ω, t) is assumed to be time-var… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
58
0

Year Published

2014
2014
2019
2019

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 66 publications
(58 citation statements)
references
References 39 publications
(56 reference statements)
0
58
0
Order By: Relevance
“…The muscle impedance was measured using a custom broadband impedance frequency response analyzer (FRA) [12], [15], [16]. The impedance measurement system was implemented on a rugged PC-platform PXI (PCI eXtensions for Instrumentation) platform from National Instruments.…”
Section: E Impedance Measurementmentioning
confidence: 99%
See 1 more Smart Citation
“…The muscle impedance was measured using a custom broadband impedance frequency response analyzer (FRA) [12], [15], [16]. The impedance measurement system was implemented on a rugged PC-platform PXI (PCI eXtensions for Instrumentation) platform from National Instruments.…”
Section: E Impedance Measurementmentioning
confidence: 99%
“…To perform simultaneous EIM spectroscopy measurements (1 kHz to 1 MHz), multisine impedance spectroscopy is used [12]. To fully achieve time-synchronization, both the force exerted by the muscle and the nerve stimuli applied are recorded simultaneously to the muscle impedance measurement.…”
mentioning
confidence: 99%
“…based on multisines signals [10], [11], [12]. Using the multifrequency approach, many frequencies are applied simultaneously (B) and the time to acquire a complete EIM spectrum is drastically reduced making it possible to measure the instantaneous impedance changes and temporal evolution of dynamic EIM, for example, during muscle contraction and relaxation and to collect both nonand fatigued muscle data.…”
Section: Impedance Instrumentationmentioning
confidence: 99%
“…The muscle impedance was measured using the custom broadband impedance frequency response analyzer (FRA) used in [11], [12]. The impedance measurement system was implemented on a rugged PC-platform PXI (PCI eXtensions for Instrumentation) platform from National Instruments.…”
Section: Impedance Measurementmentioning
confidence: 99%
“…Sanchez et al have recently introduced a new measuring approach based on multi-sine EBIS for time-varying bioimpedance monitoring [14]. This method and other multi-frequency excitation methods allows for higher sampling rates of the EBIS signal.…”
Section: Introductionmentioning
confidence: 99%