1993
DOI: 10.1063/1.1143963
|View full text |Cite
|
Sign up to set email alerts
|

A new instrument for spatially resolved laser desorption/laser multiphoton ionization mass spectrometry

Abstract: Articles you may be interested inElemental and isotopic analysis of inorganic salts by laser desorption ionization mass spectrometry AIP Conf.A high resolution dual mass gate for ion separation in laser desorption/ionization time of flight mass spectrometry Rev.Ultrasensitive fingerprint detection of organometallic compounds by laser multiphoton ionization mass spectrometry Appl. Phys. Lett. 45, 1175Lett. 45, (1984; 10.1063/1.95082Laser ionization mass spectrometry: Extensive fragmentation via resonanceenhan… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
32
0
1

Year Published

1995
1995
2010
2010

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 31 publications
(34 citation statements)
references
References 18 publications
1
32
0
1
Order By: Relevance
“…This laser beam geometry gives a larger ionization volume and should increase the system sensitivity and allow the measure of mass spectra for significantly lower laser fluences than that possible with a spot focused laser. It is noted from the literature that Zenobi and co-workers [16,17] used a focused laser sheet for the ionization process.…”
Section: Methodsmentioning
confidence: 98%
See 1 more Smart Citation
“…This laser beam geometry gives a larger ionization volume and should increase the system sensitivity and allow the measure of mass spectra for significantly lower laser fluences than that possible with a spot focused laser. It is noted from the literature that Zenobi and co-workers [16,17] used a focused laser sheet for the ionization process.…”
Section: Methodsmentioning
confidence: 98%
“…For this purpose various strategies have been suggested including REMPI for selective ionization [16,18,19]. However, Haefliger and Zenobi demonstrated that single wavelength, two photon REMPI is not very selective for desorbed PAH because of the high temperature of the PAH gas [17].…”
Section: Evolution Of the Mass Spectra With The Ionization Fluence: Smentioning
confidence: 99%
“…For example, PM on filters was characterized by infrared (IR) laser desorption followed by resonance twophoton ionization (R2PI) with an UV laser. 159 Matrix effects that can deleteriously affect quantitation are eliminated by liberating neutral species from the particles with the IR laser pulse in the first step. This approach was applied to different types of samples including ambient organic aerosols, 160,161 tobacco smoke, 162 and PAHs.…”
Section: Anion-exchange Chromatographymentioning
confidence: 99%
“…The development of new ion sources such as matrix‐assisted laser desorption/ionisation (MALDI)2 and electrospray ionisation (ESI)3 has further stimulated improvements in TOFMS, which has now become the mass analyser of choice for many applications, particularly in the biosciences. Our group4 and others5–8 have developed the use of laser desorption/laser ionisation TOFMS, or L2MS, for in situ analysis of large organic molecules. Time‐of‐flight mass spectrometry lends itself well to the study of metal clusters, as the technique is ideally suited to pulsed sources such as laser vaporisation (LVS) and pulsed arc cluster ion sources (PACIS).…”
mentioning
confidence: 99%