2016
DOI: 10.5194/amt-9-2709-2016
|View full text |Cite
|
Sign up to set email alerts
|

A new high-transmission inlet for the Caltech nano-RDMA for size distribution measurements of sub-3 nm ions at ambient concentrations

Abstract: Abstract. Reliable and reproducible measurements of atmospheric aerosol particle number size distributions below 10 nm require optimized classification instruments with high particle transmission efficiency. Almost all differential mobility analyzers (DMAs) have an unfavorable potential gradient at the outlet (e.g., long column, Vienna type) or at the inlet (nano-radial DMA), preventing them from achieving a good transmission efficiency for the smallest nanoparticles. We developed a new high-transmission inlet… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 14 publications
(8 citation statements)
references
References 56 publications
0
8
0
Order By: Relevance
“…In addition, charging probability decreases with size. At 15 nm, the fraction of singly negatively charged particles is less than 0.07 (Fuchs, 1963;Tigges et al, 2015) for the soft X-ray charger used here. For an aerosol of multi component composition, it applies that the more particle mass is collected, the more substances overcome the lower detection limit and the more detailed the observed mass spectrum will be.…”
Section: Mass Fraction Of Individual Substances From Time Integrated mentioning
confidence: 96%
“…In addition, charging probability decreases with size. At 15 nm, the fraction of singly negatively charged particles is less than 0.07 (Fuchs, 1963;Tigges et al, 2015) for the soft X-ray charger used here. For an aerosol of multi component composition, it applies that the more particle mass is collected, the more substances overcome the lower detection limit and the more detailed the observed mass spectrum will be.…”
Section: Mass Fraction Of Individual Substances From Time Integrated mentioning
confidence: 96%
“…The classified aerosol flow channel consists of two sections (i.e., one at high voltage and the other at electrical ground) separated by an insulated section. Since the effective way to minimize particle electrostatic loss when transporting from high voltage to ground sections of the flow channel (Bezantakos et al, 2015;Tammet, 2015;Franchin et al, 2016) is not available, we simply reduce the length of the insulation section to reduce the time needed for classified particles to pass through.…”
Section: Construction Of the Mini-cydmamentioning
confidence: 99%
“…Recent developments in diethylene glycol (DEG) condensation particle counters (CPC, Iida et al, 2009;Vanhanen et al, 2011) made it feasible to develop new scanning mobility particle spectrometers (SMPS) for extending aerosol size distribution measurement from ~3 nm down to ~1 nm (Jiang, et al, 2011a;Franchin et al, 2016). These new spectrometers were deployed in atmospheric observations (Jiang, et al, 2011b) and in chamber measurements (Franchin et al, 2016) to study NPF. A miniature cylindrical differential mobility analyser (mini-cyDMA, Cai et al, 2017) was developed to improve the performance of the DEG SMPS.…”
mentioning
confidence: 99%