2012 11th International Conference on Environment and Electrical Engineering 2012
DOI: 10.1109/eeeic.2012.6221511
|View full text |Cite
|
Sign up to set email alerts
|

A new fuzzy fault locator for series compensated transmission lines

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
2
2

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(1 citation statement)
references
References 10 publications
0
1
0
Order By: Relevance
“…For system protection setup and design, fault location is one parameter used to analyze with protection equipment as relay. About studying fault location indentifying method in the past researches, there have been many methods such as using fuzzy logic for analyzing fault location (1) , measuring parameter from system as voltage, current (2)-(4) , impedance (5)- (6) and phasor (7) , or measuring traveling wave from starting and ending points of distribution line (8) as used Park's Transformation to transfer 3 phases current to 2 phase DC current for finding differential value of waveform (9) , design location fault method from travelling wave in distribution system containing series capacitor for power factor increasing (10) , fault locating efficiently between hybrid distribution system and overhead line by travelling wave studying (11) . From the above methods, this paper focuses on current traveling wave method for characteristic study of system when fault occurs.…”
Section: Introductionmentioning
confidence: 99%
“…For system protection setup and design, fault location is one parameter used to analyze with protection equipment as relay. About studying fault location indentifying method in the past researches, there have been many methods such as using fuzzy logic for analyzing fault location (1) , measuring parameter from system as voltage, current (2)-(4) , impedance (5)- (6) and phasor (7) , or measuring traveling wave from starting and ending points of distribution line (8) as used Park's Transformation to transfer 3 phases current to 2 phase DC current for finding differential value of waveform (9) , design location fault method from travelling wave in distribution system containing series capacitor for power factor increasing (10) , fault locating efficiently between hybrid distribution system and overhead line by travelling wave studying (11) . From the above methods, this paper focuses on current traveling wave method for characteristic study of system when fault occurs.…”
Section: Introductionmentioning