2010 17th IEEE International Symposium on the Physical and Failure Analysis of Integrated Circuits 2010
DOI: 10.1109/ipfa.2010.5532005
|View full text |Cite
|
Sign up to set email alerts
|

A new FA method used for OTP disturbance failure

Abstract: In this paper, a new FA method was proposed and successfully used in the OTP (one time programmable) memory disturbance failure. The traditional FA method PVC (positive voltage contrast) is employed to detect the failed location, but it failed to find it. The more sensitive method, AFP biased current image was also failed to locate the failed location. The new method uses the light to stimulus the sample, and use AFP to scan and measure the induced current. The abnormal contrast was observed. The EFA was perfo… Show more