2012
DOI: 10.1016/j.jim.2012.01.002
|View full text |Cite
|
Sign up to set email alerts
|

A new enzyme-linked immunosorbent assay recognizing both rat and human activated coagulation Factor XII (FXIIa)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2012
2012
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 27 publications
0
3
0
Order By: Relevance
“…Assuming that a rat has ~15 ml of blood containing ~40 μg/ml of FXII zymogen [ 20 ] (600 μg for a 300 g rat), the total dose of β-FXIIa infused over 60 min (5.1 μg/kg of body weight; 1.53 μg for a 300 g rat), which represents ~0.26% of its total FXII zymogen, can be considered to lie well within its physiological range. Alternatively, based on the Beer–Lambert law, where concentration is proportional to absorbance, the circulating FXIIa levels (0.86±0.05 A 550 units) were approximately <0.63% of the total FXII zymogen content (1.37±0.09 A 550 units; RAT a diluted 1:100) [ 21 ].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Assuming that a rat has ~15 ml of blood containing ~40 μg/ml of FXII zymogen [ 20 ] (600 μg for a 300 g rat), the total dose of β-FXIIa infused over 60 min (5.1 μg/kg of body weight; 1.53 μg for a 300 g rat), which represents ~0.26% of its total FXII zymogen, can be considered to lie well within its physiological range. Alternatively, based on the Beer–Lambert law, where concentration is proportional to absorbance, the circulating FXIIa levels (0.86±0.05 A 550 units) were approximately <0.63% of the total FXII zymogen content (1.37±0.09 A 550 units; RAT a diluted 1:100) [ 21 ].…”
Section: Methodsmentioning
confidence: 99%
“…Plasma was separated and stored at −80°C in approximately 100 μl aliquots for analysis. Plasma β-FXIIa was measured using a novel FXIIa ELISA that employs mAb (monoclonal antibody) 201/9 which binds to conformational epitopes on the heavy chain of β-FXIIa and exhibits no cross-reactivity with FXII zymogen or FXIIa–inhibitor complexes [ 21 ]. Adrenaline and noradrenaline concentrations were determined using HPLC with electrochemical detection [ 22 ].…”
Section: Methodsmentioning
confidence: 99%
“…From these values SV, CO and TPR were derived, as previously described [9]. Subsequently, blood ($500 ml) was collected for FXIIa analysis using a rat ELISA without cross-reactivity with FXII zymogen or FXIIa:inhibitor complexes [24]. A second ($500 ml) sample was collected for plasma epinephrine (E) and norepinephrine (NE) determination [25].…”
Section: Experimental Designmentioning
confidence: 99%