2011 IEEE Power and Energy Society General Meeting 2011
DOI: 10.1109/pes.2011.6039244
|View full text |Cite
|
Sign up to set email alerts
|

A new dynamic strategy for improved ride-through capability of wind turbine generator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
7
0

Year Published

2012
2012
2019
2019

Publication Types

Select...
3
3

Relationship

2
4

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 11 publications
0
7
0
Order By: Relevance
“…The protection requirements and their solutions are addressed in Hernández et al and Bahmanifirouzi et al in an elaborate way. The interconnection and safe operating phenomena of induction generator used in wind power plants were addressed in Wei et al and Wang et al…”
Section: Introductionmentioning
confidence: 99%
“…The protection requirements and their solutions are addressed in Hernández et al and Bahmanifirouzi et al in an elaborate way. The interconnection and safe operating phenomena of induction generator used in wind power plants were addressed in Wei et al and Wang et al…”
Section: Introductionmentioning
confidence: 99%
“…As DBR has only the active power control ability, it is good idea to incorporate reactive power compensating device along with DBR. For stability augmentation of fixed speed WTGS, series dynamic braking resistor (SDBR) [29][30][31] is more effective than DBR with shunt-connected topology [26][27][28]. In [29][30], a simulation analysis is performed using only one fixed speed WTGS that connects the grid.…”
Section: Introductionmentioning
confidence: 99%
“…That study is symmetrical to distributed topology where each SDBR is connected close to the individual wind generators and differs significantly from the centralized topology using only one SDBR installed at the wind farm terminal. Incorporation of SDBR with dynamic voltage restorer (DVR) increases the system cost due to the presence of transformer and LC filter [31]. In the earlier works with SDBR [29][30][31], the effect of other synchronous generators that exist in a realistic power system is not evident.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Many devices, such as static var compensator (SVC), dynamic voltage restorers (DVR), Static Synchronous Compensators (STATCOM) etc have been shown to improve FRT of WECS, but they will also increase the overall cost of the system [8][9]. In [10], a non linear controller design for power converter based WT system is presented which ensures that current levels remain within design limits, even at greatly reduced voltage levels.…”
Section: Introductionmentioning
confidence: 99%