2012
DOI: 10.1002/mop.27073
|View full text |Cite
|
Sign up to set email alerts
|

A new compact multiband antenna for stroke diagnosis system over 0.5–3 GHz

Abstract: A new compact multiband antenna for stroke diagnosis systems over 0.5-3 GHz -the miniaturized self-grounded Bow-Tie antenna in a compact water-filled cylindrical bolus is designed. A prototype of the antenna has been manufactured. Simulated and measured results have shown a low reflection coefficient, directional radiation characteristic and a low radiation leakage-out ratio of the antenna.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
15
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
4
3
2

Relationship

2
7

Authors

Journals

citations
Cited by 19 publications
(15 citation statements)
references
References 12 publications
0
15
0
Order By: Relevance
“…Hence, in order to provide a more practical way to use and make benefit from coupling medium in MWI systems, the local use of coupling medium only in the direct path between the antennas and the human body was considered. In References 9 and 10, a compact self‐ground bowtie and a V‐shaped slot and short‐circuiting wall triangular patch using a water‐filled cylinder and a water bag as the coupling medium are introduced. Although these antennas provide a relatively small footprint, neither of them provides wideband characteristics.…”
Section: Introductionmentioning
confidence: 99%
“…Hence, in order to provide a more practical way to use and make benefit from coupling medium in MWI systems, the local use of coupling medium only in the direct path between the antennas and the human body was considered. In References 9 and 10, a compact self‐ground bowtie and a V‐shaped slot and short‐circuiting wall triangular patch using a water‐filled cylinder and a water bag as the coupling medium are introduced. Although these antennas provide a relatively small footprint, neither of them provides wideband characteristics.…”
Section: Introductionmentioning
confidence: 99%
“…The perpendicular component of E-field should be small in order to reduce the power absorption at the fatmuscle transitions and heating of subcutaneous tissues. An attempt to utilise the design for stroke diagnosis system resulted in a multiband antenna operating in frequency band of 0.5-3 GHz [20]. This antenna is, however, not appropriate for hyperthermia, due to the limited number of available frequencies below 1 GHz and inability to handle self-heating effect at high powers.…”
Section: Introductionmentioning
confidence: 99%
“…Due to the flexibility and good performance, the selfgrounded antennas have been applied or under investigation to the following areas: i) UWB indoor and through-wall radar with precise ranging and tracking due to the wideband performance, fast time-domain impulse response and the compact size [14]; ii) wideband MIMO systems due to the large coverage, good polarization balance and high diversity gain [8], [15]; iii) stroke diagnosis system due to the good near field aperture distribution [16]; iv) UWB SAR imaging of near field object for industrial process [17], [18]; v) breathing and heartbeat detection [19]. vi) receiving antenna on moving vehicles, such as on boats, trains and cars, because of its good Axial Ratio over large elevation angles and low profile.…”
Section: Applicationsmentioning