“…In addition, the measured δ 13 C values were also consistent with the reference values for OX-II, IAEA-C7 and IAEA-C8, indicating that the MICADAS was stable and reliable for measurement of the prepared samples. The measured pMC values for OXII, IAEA-C7, and IAEA-C8 by MICADAS at Lanzhou University were found to be comparable with the values obtained by Dongguk University (Republic of Korea) (Lee et al 2020), and the Centro Nacional de Aceleradores (Spain) (Guerra et al 2019). The background level for the MICADAS at Lanzhou University was also found to be comparable with the AMS value reported by Beijing University (Liu et al 2007).…”
Section: Accelerator Mass Spectrometersupporting
confidence: 80%
“…In addition, the measured δ 13 C values were also consistent with the reference values for OX-II, IAEA-C7 and IAEA-C8, indicating that the MICADAS was stable and reliable for measurement of the prepared samples. The measured pMC values for OXII, IAEA-C7, and IAEA-C8 by MICADAS at Lanzhou University were found to be comparable with the values obtained by Dongguk University (Republic of Korea) (Lee et al 2020), and the Centro Nacional de Aceleradores (Spain) (Guerra et al 2019). The background level for the MICADAS at Lanzhou University was also found to be comparable with the AMS value reported by Beijing University (Liu et al 2007).…”
Section: Accelerator Mass Spectrometersupporting
confidence: 80%
“…Although AMS is widely considered the standard method with the highest precision, it requires large, highly sophisticated, and expensive analytical facilities with high operating costs. Recently, some efforts have been made to make AMS more economical by reducing equipment size and associated costs. Several emerging analytical alternatives have shown potential to address these challenges and may be applicable in coprocessing.…”
Section: Advanced Methods For Tracking Biogenic Carbonmentioning
confidence: 99%
“…Pure CO 2 gas was reacted with iron powder and H 2 at 550°C for approximately 3 hr, generating graphite powder along with iron. The graphite samples were pressed into an aluminum cathode using a pneumatic sample press (Ionplus AG, Switzerland) to measure the carbon isotope ratio (Lee et al 2020a(Lee et al , 2020b.…”
Section: Chemical Pretreatment and Graphitizationmentioning
confidence: 99%
“…The samples were measured using a MICADAS accelerator mass spectrometer at Dongguk University (Lee et al 2020a). Oxalic Acid II (NIST-SRM 4990C) samples and IAEA-C1 samples were measured to normalize sample data and check the background of the AMS.…”
Section: Measurements and Calculationsmentioning
confidence: 99%