2011
DOI: 10.1109/tie.2010.2070773
|View full text |Cite
|
Sign up to set email alerts
|

A Natural Soft-Commutation PWM Scheme for Current Source Converter and Its Logic Implementation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
13
0
2

Year Published

2013
2013
2022
2022

Publication Types

Select...
4
4
1

Relationship

0
9

Authors

Journals

citations
Cited by 35 publications
(15 citation statements)
references
References 22 publications
0
13
0
2
Order By: Relevance
“…(3) and (4), the d-axis error current I doff1 and q-axis error current I qoff1 between CSI 1 and CSI 2 are obtained. Note that this calculation is in the controller of CSI 1 , so I d1 and I q1 are in the position of dividend in (3) and (4). Then the error currents between I d1 , I d2 , I q1 and I q2 will be compared with 0 because if there is no circulating current between parallel inverters, the error currents I doffx and I qoffx (x=1,2) will be 0, and the other one purpose is to define the direction of the compensation.…”
Section: A the Anayisis Of Circulating Currentmentioning
confidence: 99%
See 1 more Smart Citation
“…(3) and (4), the d-axis error current I doff1 and q-axis error current I qoff1 between CSI 1 and CSI 2 are obtained. Note that this calculation is in the controller of CSI 1 , so I d1 and I q1 are in the position of dividend in (3) and (4). Then the error currents between I d1 , I d2 , I q1 and I q2 will be compared with 0 because if there is no circulating current between parallel inverters, the error currents I doffx and I qoffx (x=1,2) will be 0, and the other one purpose is to define the direction of the compensation.…”
Section: A the Anayisis Of Circulating Currentmentioning
confidence: 99%
“…The current-source inverter (CSI) offers advantages over voltage source inverter (VSI) in terms of inherent boosting and short-circuit protection capabilities, direct output current controllability, and ac-side simpler filter structure [1], [2]. These features make it attractive in many UPS applications [3], such as high speed elevators, high-power electric drives and distributed generation systems as an interface between the utility grid and distributed power sources [4].…”
Section: Introductionmentioning
confidence: 99%
“…The circuit layout is carefully designed to avoid stray inductances between the current paths of the transistors of each module, helping to reduce the switching losses. An additional SPWM scheme for natural soft commutation to increase the overall efficiency can be found in [34].…”
Section: B Experimental Setupmentioning
confidence: 99%
“…Besides, there is a potential risk of overcurrent due to the phase-leg short circuit, which reduces the system reliability. On the other hand, the current source converters have the inherent current limiting capability and thus enhance the reliability [8][9][10][11]. Furthermore, they allow forbidden states in the case of voltage source converters that may cause short-circuit, being in case of current source a desirable possibility to achieve soft-switching operation [12].…”
mentioning
confidence: 99%