2019
DOI: 10.1007/s00604-018-3178-7
|View full text |Cite
|
Sign up to set email alerts
|

A nanocomposite consisting of porous graphitic carbon nitride nanosheets and oxidized multiwalled carbon nanotubes for simultaneous stripping voltammetric determination of cadmium(II), mercury(II), lead(II) and zinc(II)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
15
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 68 publications
(20 citation statements)
references
References 33 publications
2
15
0
Order By: Relevance
“…2f shows the ring pattern and diffraction spots, which are indexed to the (002), (101), (200), (211) and (220) crystalline planes of the graphitic nitride, g-C 3 N 4 , and single crystalline tetragonal b-Sn, respectively. [12][13][14] The SAED results in Fig. 2f are consistent with the ndings obtained from the XRD and XPS results that will be described below.…”
Section: Resultssupporting
confidence: 85%
“…2f shows the ring pattern and diffraction spots, which are indexed to the (002), (101), (200), (211) and (220) crystalline planes of the graphitic nitride, g-C 3 N 4 , and single crystalline tetragonal b-Sn, respectively. [12][13][14] The SAED results in Fig. 2f are consistent with the ndings obtained from the XRD and XPS results that will be described below.…”
Section: Resultssupporting
confidence: 85%
“…Researchers have improved by introducing oxidized multi-wall carbon nanotubes (O–MWCNTs) on a 3D porous graphitic carbon nitride (g-C 3 N 4 ). The nanocomposite was modified on a screen-printed electrode (SPE) for the simultaneous detection of Pb 2+ , Cd 2+ , Zn 2+, and Hg 2+ [ 28 ]. Different electrochemical techniques such as cyclic voltammetry, electrochemical impedance spectroscopy, and differential pulse voltammetry were used to interrogate the quantification of these analytes.…”
Section: Multifunctional Applications Of Graphitic Carbon Nitride mentioning
confidence: 99%
“…Therefore, these analytes’ simultaneous detection was possible because of well-separated peaks potentials of 0.5, −0.78, −11.6, and +0.35 V (vs. Ag/AgCl). The analytes’ detection limits were between 8 to 60 ng/L, and the simultaneous detection of these ions was also carried out in various spiked food samples [ 28 ]. Based on the obtained results, this sensor is highly recommendable owing to the conducting substrate used for the analysis.…”
Section: Multifunctional Applications Of Graphitic Carbon Nitride mentioning
confidence: 99%
See 2 more Smart Citations