2019
DOI: 10.1002/mp.13696
|View full text |Cite
|
Sign up to set email alerts
|

A multitransmit external body array combined with a 1H and 31P endorectal coil to enable a multiparametric and multimetabolic MRI examination of the prostate at 7T

Abstract: Purpose In vivo 1H and 31P magnetic resonance spectroscopic imaging (MRSI) provide complementary information on the biology of prostate cancer. In this work we demonstrate the feasibility of performing multiparametric imaging (mpMRI) and 1H and 31P spectroscopic imaging of the prostate using a 31P and 1H endorectal radiofrequency coil (ERC) in combination with a multitransmit body array at 7 Tesla (T).MethodsAn ERC with a 31P transceiver loop coil and 1H receive (Rx) asymmetric microstrip (31P/1H ERC) was desi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
10
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 8 publications
(10 citation statements)
references
References 24 publications
0
10
0
Order By: Relevance
“…To allow 3D coverage of the entire prostate, the combination of a body array transmit coil and ERC for reception was tested by Lagemaat et al [ 41 ]. This combination of a transmit surface array coil and receive ERC was able to provide a homogeneous B 1 + field in the prostate with detection at high SNR [ 41 , 56 ]. Patients were subjected to an mpMRI examination, consisting of T 2 w, DWI, and 1 H-MRSI.…”
Section: Assessment Of Metabolite Ratios Within the Prostate With ...mentioning
confidence: 99%
See 4 more Smart Citations
“…To allow 3D coverage of the entire prostate, the combination of a body array transmit coil and ERC for reception was tested by Lagemaat et al [ 41 ]. This combination of a transmit surface array coil and receive ERC was able to provide a homogeneous B 1 + field in the prostate with detection at high SNR [ 41 , 56 ]. Patients were subjected to an mpMRI examination, consisting of T 2 w, DWI, and 1 H-MRSI.…”
Section: Assessment Of Metabolite Ratios Within the Prostate With ...mentioning
confidence: 99%
“…In a 7 T mpMRI feasibility study by Philips et al [ 56 ], using a 31 P/ 1 H ERC with an external 1 H transceiver body array and spectral-spatial refocusing pulses, 1 H-MRSI spectra were acquired from three patients. Adequate SNR was seen from apex to base of the prostate resulting in spectra with well distinguishable choline and spermine signals, while citrate in some cases suffered from lipid contamination.…”
Section: Assessment Of Metabolite Ratios Within the Prostate With ...mentioning
confidence: 99%
See 3 more Smart Citations