A multichannel visible spectroscopy system for the ITER-like W divertor on EAST

Abstract: To facilitate long-pulse high power operation, an ITER-like actively cooled tungsten (W) divertor was installed in Experimental Advanced Superconducting Tokamak (EAST) to replace the original upper graphite divertor in 2014. A dedicated multichannel visible spectroscopic diagnostic system has been accordingly developed for the characterization of the plasma and impurities in the W divertor. An array of 22 lines-of-sight (LOSs) provides a profile measurement of the light emitted from the plasma along upper oute… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
32
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 41 publications
(34 citation statements)
references
References 19 publications
0
32
0
Order By: Relevance
“…The spectroscopic diagnostic for detecting the influx of impurity at the tungsten divertor region has been utilized. 24 The line emissions intensity of tungsten (W), oxygen (O), nitrogen (N), lithium (Li), and carbon (C), normalized to the D Balmer line (D d , 410.06 nm) measured by the divertor spectroscopy versus loss powers across the separatrix, P loss , are shown in Fig. 6, with respect to two field directions, which are averaged over a time interval of 10 ms in the Lmode phase just prior to the L-H transition.…”
Section: A the Impurity Levels And Edge Neutral Particlesmentioning
confidence: 99%
“…The spectroscopic diagnostic for detecting the influx of impurity at the tungsten divertor region has been utilized. 24 The line emissions intensity of tungsten (W), oxygen (O), nitrogen (N), lithium (Li), and carbon (C), normalized to the D Balmer line (D d , 410.06 nm) measured by the divertor spectroscopy versus loss powers across the separatrix, P loss , are shown in Fig. 6, with respect to two field directions, which are averaged over a time interval of 10 ms in the Lmode phase just prior to the L-H transition.…”
Section: A the Impurity Levels And Edge Neutral Particlesmentioning
confidence: 99%
“…The measured radiances from excited neutral W atoms can, therefore, be converted into W atom fluxes from the targets. A multichannel spectroscopic system was built on EAST to dedicatedly measure the emission lines of impurities in the upper W divertor region [13]. This system has a vertical array of 22 LOSs directed at the outer target and 17 LOSs at the inner target, respectively, which provides profile measurements of W sources along both divertor targets with a 13 mm poloidal resolution ( Fig.…”
Section: In-situ Monitoring Of W Sputtering Sourcementioning
confidence: 99%
“…Two types of spectroscopic detecting systems are used for the Reproduced with permission from Ref. [13]. Copyright 2017 AIP Publishing analysis of the plasma emission light transmitted through fibers.…”
Section: In-situ Monitoring Of W Sputtering Sourcementioning
confidence: 99%
See 1 more Smart Citation
“…The collected light is transmitted via 40 m ultraviolet hard cladding silica optical fibers to a Czerny Turner spectrometer and then focused on an EM-CCD camera. A detailed description of this spectroscopic system is given in [12]. With vertical binning, a simultaneous measurement of 16 LOSs with temporal resolution of 5.3 ms can be achieved.…”
Section: Introductionmentioning
confidence: 99%