In order to withstand rapid increase in particle and power impact onto the divertor and demonstrate the feasibility of the ITER design under long pulse operation, the upper divertor of the EAST tokamak has been upgraded to actively water-cooled, ITER-like tungsten mono-block structure since the 2014 campaign, which is the first attempt for ITER on the tokamak devices. Therefore, a new divertor Langmuir probe diagnostic system (DivLP) was designed and successfully upgraded on the tungsten divertor to obtain the plasma parameters in the divertor region such as electron temperature, electron density, particle and heat fluxes. More specifically, two identical triple probe arrays have been installed at two ports of different toroidal positions (112.5-deg separated toroidally), which can provide fundamental data to study the toroidal asymmetry of divertor power deposition and related 3-dimension (3D) physics, as induced by resonant magnetic perturbations, lower hybrid wave, and so on. The shape of graphite tip and fixed structure of the probe are designed according to the structure of the upper tungsten divertor. The ceramic support, small graphite tip, and proper connector installed make it possible to be successfully installed in the very narrow interval between the cassette body and tungsten mono-block, i.e., 13.5 mm. It was demonstrated during the 2014 and 2015 commissioning campaigns that the newly upgraded divertor Langmuir probe diagnostic system is successful. Representative experimental data are given and discussed for the DivLP measurements, then proving its availability and reliability.
A total power injection up to 0.3 GJ has been achieved in EAST long pulse H-mode operation of 101.2 s with an ITER-like water-cooled tungsten (W) mono-block divertor, which has steady-state power exhaust capability of 10 MWm−2. The peak temperature of W target saturated at 12 s to the value T ~ 500 °C with a heat flux ~3.3 MW m−2 being maintained during the discharge. By tailoring the 3D divertor plasma footprint through edge magnetic topology change, the heat load was broadly dispersed and thus peak heat flux and W sputtering were well controlled. Active feedback control of H-mode detachment with D2 fuelling or divertor impurity seeding has been achieved successfully, with excellent compatibility with the core plasma performance. Active feedback control of radiative power utilizing neon seeding was achieved with f rad = 18%–41% in H-mode operation, exhibiting potential for heat flux reduction with divertor and edge radiation. This has been further demonstrated in DIII-D high β P H-mode scenario within the joint DIII-D/EAST experiment using impurity seeding from the divertor volume. Steady-state particle control and impurity exhaust has been achieved for long pulse H-mode operation over 100 s with the W divertor by leveraging the effect of drifts and optimized divertor configuration, coupled with strong pumping and extensive wall conditioning. Approaches toward the reduction of divertor W sourcing, which is of crucial importance for a metal-wall tokamak, are also explored. These advances provide important experimental information on favourable core-edge integration for high power, long-pulse H-mode operation in EAST, ITER and CFETR.
The Experimental Advanced Superconducting Tokamak (EAST) has recently achieved a variety of H-mode regimes with different edge-localized mode (ELM) dynamics, including type-I ELMs, compound ELMs, which are manifested by the onset of a large spike followed by a sequence of small spikes on Dα emissions, usual type-III ELMs, and very small ELMs. This newly observed very small ELMy H-mode appears to be similar to the type-II ELMy H-mode, with higher repetition frequency (∼1 kHz) and lower amplitude than the type-III ELMy H-mode, exhibiting an intermediate confinement level between type-I and type-III ELMy H-modes. The energy loss and divertor power load are systematically characterized for these different ELMy H-modes to provide a physics basis for the next-step high-power long-pulse operations in EAST. Both type-I and compound ELMs exhibit good confinement (H98(y,2) ∼ 1). A significant loss of the plasma stored energy occurs at the onset of type-I ELMs (∼8%) and compound ELMs (∼5%), while no noticeable change in the plasma stored energy is observed for the small ELMs, including both type-III ELMs and very small ELMs. The peak heat flux on divertor targets for type-I ELMs currently achieved in EAST is about 10 MW m−2, as determined from the divertor-embedded triple Langmuir probe system with high time resolution. As expected, type-III ELMs lead to much smaller divertor power loads with a peak heat flux of about 2 MW m−2. Peak power loads for compound ELMs are between those for type-I and type-III ELMs. It is remarkable that the new very small ELMy H-modes exhibit even lower target power deposition than type-III ELMs, with the peak heat flux generally below 1 MW m−2. These very small ELMs are usually accompanied by broadband fluctuations with frequencies ranging from 20 to 50 kHz, which may promote particle and power exhaust throughout the very small ELMy H-mode regime.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.