2024
DOI: 10.1016/j.jma.2022.06.008
|View full text |Cite
|
Sign up to set email alerts
|

A multi-functional MgF2/polydopamine/hyaluronan-astaxanthin coating on the biodegradable ZE21B alloy with better corrosion resistance and biocompatibility for cardiovascular application

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 17 publications
(7 citation statements)
references
References 51 publications
0
5
0
Order By: Relevance
“…However, as the concentration of GA-PEPE increased to 25 and 50 μM, the cell viability of raw264.7 was significantly reduced ( p < 0.0001). Around the experimental group at the lowest three concentrations, the results of cell live and death staining were used to compensate for the shortcomings of CCK8 experiment Figure B–D shows the results of the cell staining.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…However, as the concentration of GA-PEPE increased to 25 and 50 μM, the cell viability of raw264.7 was significantly reduced ( p < 0.0001). Around the experimental group at the lowest three concentrations, the results of cell live and death staining were used to compensate for the shortcomings of CCK8 experiment Figure B–D shows the results of the cell staining.…”
Section: Resultsmentioning
confidence: 99%
“…Around the experimental group at the lowest three concentrations, the results of cell live and death staining were used to compensate for the shortcomings of CCK8 experiment. 67 Figure 6 B–D shows the results of the cell staining. Relatively significant cell death was observed in GA-PEPE at 12.5 μM compared to the control group, while the degree of cell death in PEPE at 3.125 μM was lower than that in CCK8.…”
Section: Resultsmentioning
confidence: 99%
“…Mg alloys and their degradation products can partially reduce endothelial proliferation, and bioresorbable Mg stents exhibit negative charges during degradation [ 51 ], which may possess potential antithrombotic properties. Studies have also demonstrated that Mg can attenuate ischemia–reperfusion injury [ 52 ], and its inhibition of endothelin-1 production can prevent endothelin-mediated vasoconstriction [ 53 , 54 ]. Bioresorbable Mg scaffolds in the field of coronary stents are still undergoing advancements.…”
Section: Types Of Mg-based Supportsmentioning
confidence: 99%
“…Surface self-assembly was the main method to prepare ECM component coatings on the surface of cardiovascular materials for a long time in the past, especially since the LbL self-assembly technology can make the ECM coating more evenly distributed on the surface, but its disadvantage is that with the increase in different layers, the stability of the coating will gradually decline at a turning point [61]. In comparison, it is simpler and more stable for different ECM components to be blended and self-assembled to the material surface as required [62]. The distribution, morphology and behavior of cells on the surface can be controlled by stamping ECM components onto the surface of materials with polymer stamps.…”
Section: Preparation Of Ecmmentioning
confidence: 99%