2018
DOI: 10.1109/tie.2017.2733488
|View full text |Cite
|
Sign up to set email alerts
|

A Modified Phase Disposition Pulse Width Modulation to Suppress the Leakage Current for the Transformerless Cascaded H-Bridge Inverters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
15
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 37 publications
(15 citation statements)
references
References 27 publications
0
15
0
Order By: Relevance
“…Huang and Huang [36] presented a PWM technique based on feedforward proportional carrier to control a single phase cascaded H-bridge MLI, which was also tested in hardware. Wang et al [37], presented a modified version of phase disposition PWM technique for driving a symmetric MLI, which achieved a THD of 4.88%. Biswas and Khan [38] presented a phase shifted carrier PWM for switching a grid-connected MLI.…”
Section: Acmentioning
confidence: 99%
“…Huang and Huang [36] presented a PWM technique based on feedforward proportional carrier to control a single phase cascaded H-bridge MLI, which was also tested in hardware. Wang et al [37], presented a modified version of phase disposition PWM technique for driving a symmetric MLI, which achieved a THD of 4.88%. Biswas and Khan [38] presented a phase shifted carrier PWM for switching a grid-connected MLI.…”
Section: Acmentioning
confidence: 99%
“…The German standard VDE-0126-1-1 obligates to disconnect PV systems from the grid within 0.3s when the rms value of the leakage current or its peak value increases beyond 30mA and 300mA respectively [10]. Methods for suppressing leakage current are categorized by: 1) decoupling or clamping the parasitic capacitance [11]- [20]; 2) inclusion of common-mode chokes or filters to provide attenuation [21]- [24]; 3) applying appropriate modulation strategies to ameliorate the issue [25]- [28]. In addition, decoupling the parasitic PV capacitances from the AC side of the circuit during the freewheeling period may suppress the leakage current such as in HERIC [12] and H5 [19] topologies.…”
Section: Introductionmentioning
confidence: 99%
“…However, when these Z source inverters are used in the field of PV power generation, the defect of the ground leakage current still exists. For the sake of eliminating the leakage current, an effective method is to make the common-mode voltage constant [16][17][18][19][20][21][22][23][24][25][26][27][28][29][30][31]. In [16,17], single-phase H5 and H6 inverters without isolation transformers are proposed, which have lowleakage current characteristics.…”
Section: Introductionmentioning
confidence: 99%