2017
DOI: 10.1016/j.aca.2017.08.024
|View full text |Cite
|
Sign up to set email alerts
|

A modified DGT technique for the simultaneous measurement of dissolved inorganic nitrogen and phosphorus in freshwaters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
16
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 31 publications
(16 citation statements)
references
References 42 publications
0
16
0
Order By: Relevance
“…Huang et al (2016a, b) compared labile concentrations determined by DGT and grab sample for NH 4 -N and NO 3 -N concentrations in freshwater, respectively. Results showed C DGT : C SOL = 0.83-1.3 for NH 4 -N, and C DGT : C SOL = 1.03-1.04 for NO 3 -N. Huang et al (2017) further measured dissolved inorganic nitrogen (PrCH resin for NH 4 -N and A520E resin for NO 3 -N) and phosphorus (Metsorb for PO 4 -P) simultaneously in freshwater using a hybrid DGT. The ratio C DGT /C SOL was 0.83-1.3 for NH 4 -N, NO 3 -N and PO 4 -P, which demonstrated a high level of measurement accuracy for the new DGT.…”
Section: Measurement Of Time-averaged Concentrationsmentioning
confidence: 96%
“…Huang et al (2016a, b) compared labile concentrations determined by DGT and grab sample for NH 4 -N and NO 3 -N concentrations in freshwater, respectively. Results showed C DGT : C SOL = 0.83-1.3 for NH 4 -N, and C DGT : C SOL = 1.03-1.04 for NO 3 -N. Huang et al (2017) further measured dissolved inorganic nitrogen (PrCH resin for NH 4 -N and A520E resin for NO 3 -N) and phosphorus (Metsorb for PO 4 -P) simultaneously in freshwater using a hybrid DGT. The ratio C DGT /C SOL was 0.83-1.3 for NH 4 -N, NO 3 -N and PO 4 -P, which demonstrated a high level of measurement accuracy for the new DGT.…”
Section: Measurement Of Time-averaged Concentrationsmentioning
confidence: 96%
“…Temporal variations in the concentration of pollutants are frequent in natural waters as a result of the dynamics of natural and anthropogenic cycles. The integrative nature of DGT passive samplers suggests that they can provide timeweighted average (TWA) concentrations of the analytes over the deployment time, in contrast with conventional grab sampling (which yields a snapshot of the sampling site at one particular moment; Allan et al, 2007;Dunn et al, 2007;Huang et al, 2016Huang et al, , 2017. The response of DGT devices to changes in concentration during the deployment time has been studied both theoretically and experimentally through DGT deployments in solutions of different concentrations during controlled time periods (Altier et al, 2019).…”
Section: Dgt As a Time-weighted Average Concentrationmentioning
confidence: 99%
“…There are a few studies in the literature about the response of DGT devices to changes in concentration during the deployment time. Some of these works deal with metals [6,17,18], but others are applied to toxic organic compounds [13,16,19,20], or to nutrients such as inorganic P or N [21][22][23]. Although most of the concepts here developed can be useful in the measurement of TWA concentrations of most analytes of environmental interest, this work focusses on the case of metals.…”
Section: Introductionmentioning
confidence: 99%