2019
DOI: 10.1016/j.aca.2019.01.056
|View full text |Cite
|
Sign up to set email alerts
|

Time weighted average concentrations measured with Diffusive Gradients in Thin films (DGT)

Abstract: Està subjecte a una llicència de Reconeixement-NoComercial-SenseObraDerivada 3.0 de Creative Commons

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
14
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 17 publications
(14 citation statements)
references
References 40 publications
0
14
0
Order By: Relevance
“…When transient effects are negligible and the deployment takes place under perfect-sink conditions (linear accumulation regime), it can be seen that c DGT corresponds to the timeweighted average of the labile concentration in the sample (Altier et al, 2019). This general result, together with the expression of c DGT in terms of the concentration of real species, Equation (3), leads to a general equation for the interpretation of c DGT in fluctuating systems.…”
Section: Dgt As a Time-weighted Average Concentrationmentioning
confidence: 86%
See 2 more Smart Citations
“…When transient effects are negligible and the deployment takes place under perfect-sink conditions (linear accumulation regime), it can be seen that c DGT corresponds to the timeweighted average of the labile concentration in the sample (Altier et al, 2019). This general result, together with the expression of c DGT in terms of the concentration of real species, Equation (3), leads to a general equation for the interpretation of c DGT in fluctuating systems.…”
Section: Dgt As a Time-weighted Average Concentrationmentioning
confidence: 86%
“…The integrative nature of DGT passive samplers suggests that they can provide timeweighted average (TWA) concentrations of the analytes over the deployment time, in contrast with conventional grab sampling (which yields a snapshot of the sampling site at one particular moment; Allan et al, 2007;Dunn et al, 2007;Huang et al, 2016Huang et al, , 2017. The response of DGT devices to changes in concentration during the deployment time has been studied both theoretically and experimentally through DGT deployments in solutions of different concentrations during controlled time periods (Altier et al, 2019). The results indicate that, if the duration of a pulsed fluctuation is much longer than the characteristic time to reach steady state (ca.…”
Section: Dgt As a Time-weighted Average Concentrationmentioning
confidence: 99%
See 1 more Smart Citation
“…Using this algorithm, analysis of rigorous digital simulation of the diffusion-reaction processes in experimental accumulation by DGT sensors in several systems led to important theoretical developments related to DGT functioning [3,[17][18][19].…”
Section: + L M + 2 L M + 14 Lmentioning
confidence: 99%
“…nitrate, iodide, Rb, etc. ), cDGT corresponds to the (time-averaged, [2]) total concentration of this species. For analytes (such as Cu) having different contributing forms (free Cu 2+ ions, inorganic complexes of copper such as hydroxides, organic Cu complexes with natural dissolved or colloidal organic matter, etc.…”
Section: Introductionmentioning
confidence: 99%