1993
DOI: 10.1016/0022-0728(93)80339-j
|View full text |Cite
|
Sign up to set email alerts
|

A mirage effect analysis of the electrochemical processes in nickel hydroxide electrodes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
8
0
1

Year Published

1995
1995
2012
2012

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 21 publications
(11 citation statements)
references
References 15 publications
1
8
0
1
Order By: Relevance
“…The fit of voltammetric dada yielded the values D Fe 3þ ¼ 4:7 Â 10 À6 cm 2 s À1 ; D Fe 2þ ¼ 8:9 Â 10 À6 cm 2 s À1 and E o Fe 3þ =Fe 2þ ¼ 0:472 V. The last datum is the standard potential of the redox reaction with regard to that of the reference electrode. Those data are in agreement with our previous results and with those found in the literature [1,8,23,34]. From the fits it was also possible to estimate the electrode area as A = 1.84 cm 2 .…”
Section: Fig 3 Shows Experimental (Circles) and Simulated (Lines) Vosupporting
confidence: 88%
See 1 more Smart Citation
“…The fit of voltammetric dada yielded the values D Fe 3þ ¼ 4:7 Â 10 À6 cm 2 s À1 ; D Fe 2þ ¼ 8:9 Â 10 À6 cm 2 s À1 and E o Fe 3þ =Fe 2þ ¼ 0:472 V. The last datum is the standard potential of the redox reaction with regard to that of the reference electrode. Those data are in agreement with our previous results and with those found in the literature [1,8,23,34]. From the fits it was also possible to estimate the electrode area as A = 1.84 cm 2 .…”
Section: Fig 3 Shows Experimental (Circles) and Simulated (Lines) Vosupporting
confidence: 88%
“…The values of on/oC j for each ionic species can be then calculated by fitting the deflection curves in the same way as that described for chronodeflectometric profiles [8]. The variables on/oC j cannot take any value since they are constantly added, according to a given stoichiometric relationship, to rebuild the global on/oC of the respective neutral salt [8,23,34].…”
Section: Application Of the Model To Fit Probe Beam Deflection Datamentioning
confidence: 99%
“…Using current pulse deflectometry techniques, the contribution of OH À to the ion exchange of nickel oxide films, 42 was found to be dominant but with a contribution of co-ions (cations). By combination of PBD with EQCM, the role of ions and solvent was demonstrated.…”
Section: Other Oxidesmentioning
confidence: 97%
“…Prior electrochemical quartz crystal microb a lance (EQCM) [20] and probe beam deflection [21] studies of Ni oxide films have indicated that cations and/^r solvent molecules are indeed exchanged during the redox reaction. In related publications [22][23][24], we ha.ve reported the electrochemical behavior and structural properties of pure Ni and 50:50 Ni-Co oxide films formed by the SG technique.…”
Section: + 4ffo + 2ementioning
confidence: 99%