2020 IEEE International Ultrasonics Symposium (IUS) 2020
DOI: 10.1109/ius46767.2020.9251619
|View full text |Cite
|
Sign up to set email alerts
|

A Miniature Rotary-linear Ultrasonic motor for Intravascular Ultrasound (IVUS) Imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
3
1
1

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 7 publications
0
5
0
Order By: Relevance
“…Post-synthesis modification is an effective means to prepare MOFs with ECL properties. The mechanism is mainly to attach luminophores to the surface of MOFs by ligand reaction, electrostatic force adsorption, or amide bonding, so that the MOFs materials, originally without ECL properties, become nanocomposites with ECL properties [79,80].…”
Section: Post-synthesis Modificationmentioning
confidence: 99%
See 1 more Smart Citation
“…Post-synthesis modification is an effective means to prepare MOFs with ECL properties. The mechanism is mainly to attach luminophores to the surface of MOFs by ligand reaction, electrostatic force adsorption, or amide bonding, so that the MOFs materials, originally without ECL properties, become nanocomposites with ECL properties [79,80].…”
Section: Post-synthesis Modificationmentioning
confidence: 99%
“…Table 1 shows the comparison between these main in vivo imaging techniques [94]. Intravascular imaging [74,78,79] Trachea imaging [77] PA imaging From sub-micrometer to sub-millimeter [94] From sub-micrometer to sub-millimeter [94] From sub-millimeter to depths up to several millimeters [94] Submillimeter [85] Millimeter [73,75,[86][87][88] Tissue imaging [85,86,88] Intravascular imaging [87]…”
Section: Other Techniquesmentioning
confidence: 99%
“…Then, a power amplifier (75A250A, Amplifier Research Inc., USA) was used to amplify these signals to 80 Vp-p, which excited the motor driving the IVUS catheter. For ultrasound transmission, the electrical signals (1 cycle sinusoidal pulse at 41.5 MHz with a pulse repetition frequency of 2500 Hz) were transmitted from the Verasonics Vantage 64LE high-frequency ultrasound system (Verasonics Inc., USA) to the single-element transducer when a synchronized trigger was obtained from the function generator [34]. Then, the same ultrasound system recorded the digitized ultrasound signals, eventually stored in a computer.…”
Section: Imaging System Designmentioning
confidence: 99%
“…The basic performance characterization of a motor, such as vibration, maximum speed, optimal working distance, rotary uniformity, positioning accuracy, and SNR competition, must be tested first before the imaging evaluation. Our proposed helical ultrasonic motor design was partially shown in a conference proceeding [34]; however, the system performance was not previously described and the conducted in vitro experiments were primitive. Fig.…”
Section: F Motor Evaluationmentioning
confidence: 99%
“…The motor could realize rotational and linear movements by changing ultrasonic motor modes. This work holds great promise for further compact system design [ 79 ].…”
Section: Probes For In Vivo Physical Sensingmentioning