A Microminiature Solid-State Capacitive Blood Pressure Transducer with Improved Sensitivity

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

1980
1980
2019
2019

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 26 publications
(10 citation statements)
references
References 3 publications
0
10
0
Order By: Relevance
“…This gave a 14% change in capacitance, which is very high relative to the 0.6% change in resistivity for a similarly scaled piezoresistive transducer. This order of magnitude greater sensitivity of capacitive transducers is due to greater relative shifts in diaphragm displacement than in diaphragm strain [27,[57][58][59][60]. Additionally, hermetic sealing of the reference chamber by anodic boding eliminated the functional need for bulky reference pressure port, such as a catheter.…”
Section: Mature Bulk Micromachiningmentioning
confidence: 99%
“…This gave a 14% change in capacitance, which is very high relative to the 0.6% change in resistivity for a similarly scaled piezoresistive transducer. This order of magnitude greater sensitivity of capacitive transducers is due to greater relative shifts in diaphragm displacement than in diaphragm strain [27,[57][58][59][60]. Additionally, hermetic sealing of the reference chamber by anodic boding eliminated the functional need for bulky reference pressure port, such as a catheter.…”
Section: Mature Bulk Micromachiningmentioning
confidence: 99%
“…The earliest applications that leveraged the integration of released microstructures and integrated electronics were pressure sensors fabricated using a MEMS-first approach [79]. In this strategy most of the MEMS-specific fabrication steps were performed prior to the electronics fabrication steps with the exception of the final device release steps.…”
Section: Mems-first Processesmentioning
confidence: 99%
“…While signal conditioning methods has always relayed on analog or mixed-signals electronics, the capacitive senor design, due to the needs of miniaturization, power consumption and costs issues, has shifted from being realized by bulk mechanical parts to microfabricated silicon dies. An early example of this device was fabricated for medical purposes by Frobenius et al [8] in 1973. In 1986 Ko [9] compares the capacitive pressure sensor with the well established piezoresistive device.…”
Section: Capacitive Pressure Sensors In Silicon Technologymentioning
confidence: 99%