A Method to Monitor Dutasteride in Rat Plasma Using Liquid-Liquid Extraction and Multiple Reaction Monitoring: Comparisons and Validation

Abstract: Three different dutasteride extraction methods were compared and a method based on liquid-liquid extraction (LLE) using methyl tert-butyl ether and methylene chloride was proved to be more effective than others for the extraction of dutasteride and finasteride, the internal standard (IS), from rat plasma. Additionally, a method composed of the LLE extraction, liquid chromatography, and multiple reaction monitoring (MRM) to target dutasteride and IS was validated by assessing specificity, linearity (r 2 = 0.999… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 12 publications
0
2
0
Order By: Relevance
“…Two to three product ions (Q3) were compared with various references. As a result, 19 drug compounds were found to be nearly identical to various references [21][22][23][40][41][42][43]. For two other compounds that either lacked references or did not match the references (emepronium and imidafenacin), their fragmentation patterns were monitored according to the collision energy obtained from LC-Q-TOF/MS analysis.…”
Section: Optimization Of the Lc-esi-ms/ms Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Two to three product ions (Q3) were compared with various references. As a result, 19 drug compounds were found to be nearly identical to various references [21][22][23][40][41][42][43]. For two other compounds that either lacked references or did not match the references (emepronium and imidafenacin), their fragmentation patterns were monitored according to the collision energy obtained from LC-Q-TOF/MS analysis.…”
Section: Optimization Of the Lc-esi-ms/ms Methodsmentioning
confidence: 99%
“…Previously, for the development of a more rapid and accurate monitoring method, drug compounds for a few prostate-related diseases or erectile dysfunction were analytical targets, and methods such as liquid chromatography and spectrometry using HPLC, HPTLC, LC-MS, and LC-ESI-MS/MS have been routinely used for analysis [16][17][18][19][20][21][22][23][24][25]. However, these methods have certain limitations such as the low number of detectable target compounds, or sample preparation could only be performed in a limited manner using matrices to exclude soft capsule type of dietary supplements, which contain oils as an ingredient [26][27][28][29].…”
Section: Introductionmentioning