2014
DOI: 10.1049/iet-gtd.2013.0111
|View full text |Cite
|
Sign up to set email alerts
|

A method for determination of harmonics responsibilities at the point of common coupling using data correlation analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
36
0
1

Year Published

2015
2015
2024
2024

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 57 publications
(38 citation statements)
references
References 21 publications
0
36
0
1
Order By: Relevance
“…The main idea of this method is to use the fluctuations of background harmonic current [10]. From Fig.3, (6) …”
Section: B Determination Of Harmonic Contributionsmentioning
confidence: 99%
“…The main idea of this method is to use the fluctuations of background harmonic current [10]. From Fig.3, (6) …”
Section: B Determination Of Harmonic Contributionsmentioning
confidence: 99%
“…In this context of concept diversity, a number of studies are based on mathematical resources, statistics, and artificial intelligence for determining the main sources that cause distortions in electric systems. Emphasis is given to the point that, in general, most of the procedures proposed along these lines of research commit themselves only to detecting disturbance sources, without establishing levels of responsibility .…”
Section: Introductionmentioning
confidence: 99%
“…Emphasis is given to the point that, in general, most of the procedures proposed along these lines of research commit themselves only to detecting disturbance sources, without establishing levels of responsibility . Furthermore, when proposing harmonic sharing, many studies do not worry about demonstrating, in an effective manner, the connection between their results and the physical principles associated with the problem, a fact that makes recognition of the effectiveness of these proposals difficult …”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Under certain condition, the harmonic voltage and current all fluctuate simultaneously. The methods above cannot reflect the variation of harmonic voltage and current while the influence of utility harmonic voltage fluctuation is considered in [19][20][21]. In the previous study of the authors, an adaptive assessment approach [19] for harmonic responsibility under utility harmonic voltage variation was proposed.…”
Section: Introductionmentioning
confidence: 99%