2011
DOI: 10.1109/jsen.2011.2169053
|View full text |Cite
|
Sign up to set email alerts
|

A Mediator Free Amperometric Bienzymatic Glucose Biosensor Using Vertically Aligned Carbon Nanofibers (VACNFs)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
6
3

Relationship

1
8

Authors

Journals

citations
Cited by 23 publications
(7 citation statements)
references
References 32 publications
0
7
0
Order By: Relevance
“…A superior electrochemical performance of aligned carbon nanofibers has been observed possibly because of a more effective electron transfer from the electroanalyte to the current collector. 52 Thus, the excellent charge transfer properties of this highly crystalline TiO 2 −NF provide a suitable platform for improved biosensor characteristics as compared to those of other materials ( Table 1 …”
Section: Resultsmentioning
confidence: 99%
“…A superior electrochemical performance of aligned carbon nanofibers has been observed possibly because of a more effective electron transfer from the electroanalyte to the current collector. 52 Thus, the excellent charge transfer properties of this highly crystalline TiO 2 −NF provide a suitable platform for improved biosensor characteristics as compared to those of other materials ( Table 1 …”
Section: Resultsmentioning
confidence: 99%
“…Vertically aligned carbon nanofiber forest arrays have been reported in literature as novel electrode structures for biosensing platforms [1] [2]. VACNF arrays represent an attractive electrode structure for electrochemical sensor platforms due to the presence of defect sites throughout the surface, which act as the oxidation and reduction reaction centers for electrochemical reactions.…”
Section: Introductionmentioning
confidence: 99%
“…Page A bienzymatic glucose biosensor that uses vertically aligned carbon nanofibers (VACNF) has been shown to detect glucose [2][3][4] . However, manufacturing VACNF is an expensive process.…”
Section: Methodology Used To Introduce the Teachers To The Research Problemmentioning
confidence: 99%
“…The teachers have learned about the engineering design and characterization concepts of carbon nanofiber (CNF) for biosensors applications through the active participation in the engineering research labs. Glucose biosensors have been shown to have increased effectiveness when their designs incorporate nanoparticles and nanostructures 1,2 .…”
mentioning
confidence: 99%