A Mathematical Model for Minimizing Add-On Operational Cost in Electrical Power Systems Using Design of Experiments Approach

Abstract: One of the key functions of the Distribution System Operators (DSOs) of<br />electrical power systems (EPS) is to minimize the transmission and<br />distribution power losses and consequently the operational cost. This<br />objective can be reached by operating the system in an optimal mode which is performed by adjusting control parameters such as on-load tap changer (OLTC) settings of transformers, generator excitation levels, and VAR compensators switching. The deviation from operation opt… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
5
3

Relationship

1
7

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 14 publications
0
5
0
Order By: Relevance
“…This function solution can be obtained with the help of statistical packages such as SPSS, S-Plus, STATISTICA, SAS and R-programming through the nonlinear estimation methods. The non-linear estimation model has been widely used in various field of studies include in study of population growth [1], predictive control [15,16], pattern recognition [17] etc. In this study, the parameter was estimated by the Rprogramming software.…”
Section: Methodsmentioning
confidence: 99%
“…This function solution can be obtained with the help of statistical packages such as SPSS, S-Plus, STATISTICA, SAS and R-programming through the nonlinear estimation methods. The non-linear estimation model has been widely used in various field of studies include in study of population growth [1], predictive control [15,16], pattern recognition [17] etc. In this study, the parameter was estimated by the Rprogramming software.…”
Section: Methodsmentioning
confidence: 99%
“…Despite the climate benefits and sustainability of the RESs, PS control operators faced two primary constraints when combining the large-power RESs into the PS. The first one, the output power of RESs highly depends on surrounding environmental circumstances and is not controlled [3][4][5][6][7]. The second one, the existent infrastructure of the PSs is not suitable for raising the penetration of RESs, which imposes the PS control operators to decrease a significant percentage of RESs.…”
Section: Introductionmentioning
confidence: 99%
“…MATLAB/SIMULINK can be used for studying TS but for relatively small power systems with limited number of machines [9]. The DIgSILENT PowerFactory software is capable to simulate all types of stability of power systems integrated with renewable energy sources [10][11][12][13][14]. In [15], the authors presented TS study for 400 kV Iraqi grid focusing on load flow program and simple TS model using Modified Euler's method.…”
Section: Introductionmentioning
confidence: 99%