2019
DOI: 10.1016/j.engfailanal.2019.02.005
|View full text |Cite
|
Sign up to set email alerts
|

A major leak in a crude oil tank: Predictable and unexpected root causes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0
1

Year Published

2020
2020
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 21 publications
(9 citation statements)
references
References 6 publications
0
8
0
1
Order By: Relevance
“…In oil tank safety monitoring, GS monitoring is of vital importance for the thin shell structure of oil tanks, to prevent severe damage such as distortion or cracking of the tank walls [ 4 , 12 , 13 ]. The prerequisite requirement of GS monitoring is to establish a stable reference point for comparison with the measurements obtained at various test points.…”
Section: Theoretical Backgroundmentioning
confidence: 99%
See 1 more Smart Citation
“…In oil tank safety monitoring, GS monitoring is of vital importance for the thin shell structure of oil tanks, to prevent severe damage such as distortion or cracking of the tank walls [ 4 , 12 , 13 ]. The prerequisite requirement of GS monitoring is to establish a stable reference point for comparison with the measurements obtained at various test points.…”
Section: Theoretical Backgroundmentioning
confidence: 99%
“…Ground settlement in oil tanks is a critical factor that can compromise their structural integrity and service life [ 1 , 2 , 3 , 4 ], as depicted in Figure 1 a. This emphasizes the importance of prioritizing GS monitoring for large scale infrastructures.…”
Section: Introductionmentioning
confidence: 99%
“…As it was studied by Cirimello et al [31], such an analysis could be expanded using even the most complicated CFD methods, wherein the authors showed that in the case of a large opening, a 2000 m 3 storage tank of crude oil could be emptied in less than a minute, while the leak flow could pose huge loadings on the containment enclosure. However, in the case study presented in this paper, such secondary effects were not considered and since the full collapse of the storage tank was assumed, fluid dynamics calculations were not necessary for this specific scenario.…”
Section: Consequences Assessmentmentioning
confidence: 99%
“…In work [27] three stages of static storage tank leaks are analyzed and a model is proposed that has been tested on small scale tank leakage for the leak alarm time. The article [28] the reasons for the failure of a tank in a crude oil refinery have been analyzed, and fracture models and hydrodynamic calculations have been developed to identify the causes of failure, as well as to reconstruct the sequence of events.…”
Section: Introductionmentioning
confidence: 99%