Our system is currently under heavy load due to increased usage. We're actively working on upgrades to improve performance. Thank you for your patience.
Insulation Materials: Testing and Applications, 3rd Volume 1997
DOI: 10.1520/stp12292s
|View full text |Cite
|
Sign up to set email alerts
|

A Logical Extension of the ASTM Standard E96 to Determine the Dependence of Water Vapour Transmission on Relative Humidity

Abstract: /npsi/ctrl?lang=en http://nparc.cisti-icist.nrc-cnrc.gc.ca/npsi/ctrl?lang=fr Access and use of this website and the material on it are subject to the Terms and Conditions set forth at http://nparc.cisti-icist.nrc-cnrc.gc.ca/npsi/jsp/nparc_cp.jsp?lang=en NRC Publications Archive Archives des publications du CNRCThis publication could be one of several versions: author's original, accepted manuscript or the publisher's version. / La version de cette publication peut être l'une des suivantes : la version prépubli… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
15
0

Year Published

1998
1998
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 17 publications
(16 citation statements)
references
References 5 publications
1
15
0
Order By: Relevance
“…Otherwise the corrections towards the resistances offered by the air layer complicate the data analysis. All assemblies are then placed in a chamber [5] maintained at 23°C and initially at approximately 30% RH. The assemblies are periodically weighed, as usual for the E 96 procedure, to confirm the steady state, and then the steady rate of mass change is recorded.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Otherwise the corrections towards the resistances offered by the air layer complicate the data analysis. All assemblies are then placed in a chamber [5] maintained at 23°C and initially at approximately 30% RH. The assemblies are periodically weighed, as usual for the E 96 procedure, to confirm the steady state, and then the steady rate of mass change is recorded.…”
Section: Methodsmentioning
confidence: 99%
“…The penneance so calculated should be correcled [5,11] for the surface resistances and the resistance offered by the still air inside the cups, common to all measurements. (This is why it is necessary to keep the thickness of the still air the same in all assemblies.…”
Section: Methodsmentioning
confidence: 99%
“…The following equation [16] The density of air can be calculated using the ideal gas law for the measured atmospheric pressure and ambient temperature. The buoyancy correction is important [15] when measured mass changes are in the range of 0 to 100 mg.…”
Section: Buoyancy Correctionmentioning
confidence: 99%
“…Since water vapor pressure is significantly lower than the atmospheric pressure, the water vapor can be treated as ideal gas (Lackey et al 1997). Therefore, based on the assumption (2), water vapor transport can be expressed as the well-known equation:…”
Section: Moisture Transport In Building Materialsmentioning
confidence: 99%
“…The water vapor permeability of air under room temperature was 2×10 -10 kg·m -1 · s -1 ·Pa -1 (Lackey et al 1997). The constant convection mass transfer coefficient, β, can be estimated using Lewis relation (Pedersen 1990):…”
Section: Parameter Determinationmentioning
confidence: 99%