1994
DOI: 10.1021/ja00104a001
|View full text |Cite
|
Sign up to set email alerts
|

A Kinetic Study of Concanavalin A Binding to Glycolipid Monolayers by Using a Quartz-Crystal Microbalance

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

5
101
0

Year Published

1998
1998
2020
2020

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 163 publications
(106 citation statements)
references
References 0 publications
5
101
0
Order By: Relevance
“…A QCM is known to provide very sensitive mass measuring devices in gas phase [6][7][8][9][10][11] and in aqueous solution. [15][16][17][18][19][20][21][22][23] Its resonance frequency decreases linearly upon the increase of mass on the QCM electrode at the nanogram level. When ssDNA is immobilized on a QCM, the hybridization behavior could be followed as a frequency decrease (mass increase) responding to the addition of complementary ssDNA in the solution.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…A QCM is known to provide very sensitive mass measuring devices in gas phase [6][7][8][9][10][11] and in aqueous solution. [15][16][17][18][19][20][21][22][23] Its resonance frequency decreases linearly upon the increase of mass on the QCM electrode at the nanogram level. When ssDNA is immobilized on a QCM, the hybridization behavior could be followed as a frequency decrease (mass increase) responding to the addition of complementary ssDNA in the solution.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, we calibrated our cased 27 MHz QCM in aqueous solution (pH 7.9, 10 mM Tris-HCl, 0.2 M NaCl, at 20˚C), analogously to the calibration of our conventional 9 MHz QCM. [18][19][20][21][22][23] A suitable amount of polymer solution was cast (0.1 -15 mg…”
Section: Introductionmentioning
confidence: 99%
“…When a mass is adsorbed on the resonator there is a shift in resonant frequency, which is related to the adsorbed mass by the Sauerbrey equation [30]. According to this relationship, the change in frequency (ΔF, Hz) is related to total mass of the adsorbed thin film layer (Δm, ng) as Δm = −0.87ΔF.…”
Section: Assembly On Qcm Resonatormentioning
confidence: 99%
“…Thus, we aim to build precise nanoassemblies of protein/polysaccharide multilayers to control the total sample per unit area, by exploiting the multiple binding sites of Con A and the multiple glucose groups of dextran [27,28]. It was hypothesized that this assembly approach would be successful based on the previous work done on multilayer films of Con A/glycogen [29] and Con A/glycolipids [30] built due to affinity between the molecules and not due to the electrostatic attractions.…”
Section: Introductionmentioning
confidence: 99%
“…Other methods to map the interactions, closely matching that of two-dimensional cell surfaces, are the Langmuir [6], the surface plasmon resonance (SPR) [7] and quartz crystal microbalance (QCM) methods [8,9] that allow the characterization of kinetic parameters, in addition to deriving equilibrium binding constants. Fluorescence based assays were also used in cases when either a fluorophore or chromophore engages in a reporter role of the recognition events [10].…”
mentioning
confidence: 99%