2007
DOI: 10.1016/j.aca.2007.03.048
|View full text |Cite
|
Sign up to set email alerts
|

A hybrid FIA/HPLC system incorporating monolithic column chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
20
0

Year Published

2008
2008
2018
2018

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 43 publications
(21 citation statements)
references
References 23 publications
0
20
0
Order By: Relevance
“…[27][28][29][30] In the present study, we compared the metabolite analysis using the Onyx monolithic column with two particulate columns under the same chromatographic conditions using a flow rate of 1 mL/min. The monolithic column was superior to the other two columns, providing a much faster elution pattern with a fair chromatographic resolution (Figure 4).…”
Section: Discussionmentioning
confidence: 99%
“…[27][28][29][30] In the present study, we compared the metabolite analysis using the Onyx monolithic column with two particulate columns under the same chromatographic conditions using a flow rate of 1 mL/min. The monolithic column was superior to the other two columns, providing a much faster elution pattern with a fair chromatographic resolution (Figure 4).…”
Section: Discussionmentioning
confidence: 99%
“…Chromolith (25 Â 4.6 mm) [34], Chromolith SpeedRod RP-18 (50 Â 4.6 mm) [35] Furosemide [30,31], norfloxacin [31] [ 30,31] Sotalol [32] Losartan [33,34], telmisartan [34], valsartan [34] [ 33,34] Verapamil, indiplon [35] Drugs of abuse CEC [36], FIA/HPLC-CID [37], HPLCfluorescence [38,39], HPLC-DAD [40] Urine [36,37,39], plasma [38,39], saliva [39], whole blood [40], solvent [37] Described in text [36], Chromolith Flash RP-18e (25 Â 4.6 mm) [37], Chromolith Performance RP-18e (50 Â 4.6 mm) [38], (100 Â 4.6 mm) [39,40] 3,4-Methylenedioxymethamphetamine, 3,4-methylenedioxyamphetamine, 4-hydroxy-…”
Section: Hplc-ms/ms [21]mentioning
confidence: 99%
“…An assay that uses a hybrid FIA/HPLC system was reported to measure opiates and biogenic amines in urine with a run time o8.0 min [37]. This system is a hybrid because it uses both tris(2,2 0 -bipyridyl)ruthenium(III) and acidic potassium permanganate for chemiluminescence detection.…”
Section: Drugs Of Abusementioning
confidence: 99%
“…In contrast, chemiluminescence reactions with neurotransmitters such as dopamine and serotonin have been studied extensively using several different permanganate (23)(24)(25)(26)(27)(28)(29) and luminol (30)(31)(32)(33)(34)(35)(36) systems and also with soluble manganese(IV) (20,21). Protocatechuic acid and caffeic acid are related dihydroxybenzenes that were identified as strong enhancers of the chemiluminescence from luminol and hexacyanoferrate(III) in previous studies (17,37).…”
Section: Selection Of Phenolic Compoundsmentioning
confidence: 99%
“…Although vanilmandelic acid and homovanillic acid are very similar in structure, it has been reported that they have markedly different effects on the chemiluminescent reaction between luminol and hexacyanoferrate(III): one enhances and the other inhibits (38,39). These compounds also respond to acidic potassium permanganate (27,28).…”
Section: Selection Of Phenolic Compoundsmentioning
confidence: 99%