2018
DOI: 10.1109/jsen.2017.2780445
|View full text |Cite
|
Sign up to set email alerts
|

A Highly Sensitive Miniaturized Impedimetric Perchlorate Chemical Sensor

Abstract: International audienc

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 39 publications
0
5
0
Order By: Relevance
“…Recently we have demonstrated the selectivity of cobaltphthalocyanine (Co(II)Pc‐PAA) towards nitride (NO 3 − ) and no interference with perchlorate anion . The selectivity of Co(II)Pc‐PAA was also carried out toward ClO4- using HPO 4 2− and NO 2 − , and no effect of these anions on the obtained response . In the present study, the selective properties of Si 3 N 4 /APTES‐MNP/Co(II)Pc‐PAA towards ClO4- have been investigated using interfering anions such as Cl − , SO 4 2− and CO 3 2− .…”
Section: Resultsmentioning
confidence: 97%
“…Recently we have demonstrated the selectivity of cobaltphthalocyanine (Co(II)Pc‐PAA) towards nitride (NO 3 − ) and no interference with perchlorate anion . The selectivity of Co(II)Pc‐PAA was also carried out toward ClO4- using HPO 4 2− and NO 2 − , and no effect of these anions on the obtained response . In the present study, the selective properties of Si 3 N 4 /APTES‐MNP/Co(II)Pc‐PAA towards ClO4- have been investigated using interfering anions such as Cl − , SO 4 2− and CO 3 2− .…”
Section: Resultsmentioning
confidence: 97%
“…The EIS method was used to investigate the electron transfer on the interface of the bare and modified AuSPEs. This technique has been widely employed for the electrochemical behavior investigation of the reaction dynamics and the membrane/solution structure (Ben Messaoud et al, 2016, 2017a, 2023. Figure 5…”
Section: Electrochemical Properties Of the Modified Electrodementioning
confidence: 99%
“…8,10,11 Owing to its presence in various foodstuffs 2,5,8,[11][12][13][14][15] and drinking water, 15,16 The EFSA Panel stipulated a chronic tolerable daily intake (TDI) of 0.3 mg kg −1 body weight (bw) per day. 16,20 In this review, we focus on the electrochemical sensing of ClO 4…”
Section: Introductionmentioning
confidence: 99%
“…17 The EFSA Panel stipulated a chronic tolerable daily intake (TDI) of 0.3 μg kg −1 body weight (bw) per day. 16,20…”
Section: Introductionmentioning
confidence: 99%