Our system is currently under heavy load due to increased usage. We're actively working on upgrades to improve performance. Thank you for your patience.
2022
DOI: 10.1109/tns.2021.3137415
|View full text |Cite
|
Sign up to set email alerts
|

A High Spatial Resolution Muon Tomography Prototype System Based on Micromegas Detector

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 22 publications
0
4
0
Order By: Relevance
“…A muon tomography experiment using four detectors were conducted by Ref. [12][13][14] and their experimental data after 24 hours of exposure are used in this work. It is challenging to apply the reconstruction algorithm directly to experimental data.…”
Section: Imaging Reconstruction Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…A muon tomography experiment using four detectors were conducted by Ref. [12][13][14] and their experimental data after 24 hours of exposure are used in this work. It is challenging to apply the reconstruction algorithm directly to experimental data.…”
Section: Imaging Reconstruction Resultsmentioning
confidence: 99%
“…In general, the reconstruction of the experimental data is quite challenging due to that the muon intensity from the cosmic ray is low. In this work, a modified ASR algorithm and PoCA algorithm was proposed and applied to experimental data generated by a one-day muon tomography experiment [12][13][14]. In this modified ASR algorithm, the event number threshold is employed to filter out edge noise and the fluctuation from the limited event numbers, and to improve image clarity.…”
Section: Discussionmentioning
confidence: 99%
“…• Currently a position resolution of the track detector better than 100 μm has already been achievable in a MST system with gas detectors, such as 85 μm of Micromegas [25] and 50 μm of GEM detetor [26]. The main advantage of the SciFi tracker lies in its solid and compact structures, which can be portable and more robust in real applications.…”
Section: Summary and Discussionmentioning
confidence: 99%
“…By visualizing all reconstructed data points and their corresponding ratio values within the measurement area, an image can be generated. A prototype of muon tomography, called the muon Scattering and Transmission imaging facility ( STC) 5 , was developed. It included eight Micromegas detectors 9 , 10 , four front-end electronics cards (FECs), a general data acquisition (DAQ) board, a server, two scintillators for trigger generation, and several high-voltage (HV) modules.…”
mentioning