2019
DOI: 10.1109/tia.2019.2935929
|View full text |Cite
|
Sign up to set email alerts
|

A High-Performance Online Uninterruptible Power Supply (UPS) System Based on Multitask Decomposition

Abstract:  Users may download and print one copy of any publication from the public portal for the purpose of private study or research.  You may not further distribute the material or use it for any profit-making activity or commercial gain  You may freely distribute the URL identifying the publication in the public portal If you believe that this document breaches copyright please contact us providing details, and we will remove access to the work immediately and investigate your claim.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 23 publications
(7 citation statements)
references
References 32 publications
0
6
0
Order By: Relevance
“…Then, ( 6) can be linearized, and set ( Ūr (t), īC (t), Ūo (t)) as the static working point of boost, which consists of the DC component (U r , i C , U o ) and the AC small signal component ( Ũr (t), ĩC (t), Ũo (t)), these mathematical descriptions are shown in (7).…”
Section: The Boost Circuitmentioning
confidence: 99%
See 1 more Smart Citation
“…Then, ( 6) can be linearized, and set ( Ūr (t), īC (t), Ūo (t)) as the static working point of boost, which consists of the DC component (U r , i C , U o ) and the AC small signal component ( Ũr (t), ĩC (t), Ũo (t)), these mathematical descriptions are shown in (7).…”
Section: The Boost Circuitmentioning
confidence: 99%
“…The inverter generates the AC power by converting DC power. The isolation transformer can be used to isolate the interference of the grid, and its primary and secondary sides are completely insulated to prevent the input voltage drop, filter out the harmonic at the load-end, and improve the power supply quality [5][6][7][8][9].…”
Section: Introductionmentioning
confidence: 99%
“…The proposed converter does not require a step-up transformer and is well suited for DC generation systems with low input levels. [2], discusses a new three-level uninterruptible power supply (UPS), which uses a push-pull boost circuit to interface with the battery bank and the DC bus. Compactness in its future implementation, another topology based on the Cuk-derived buck-boost method presented in [3].…”
Section: Introductionmentioning
confidence: 99%
“…In the event of an AC grid failure, the system immediately switches to backup mode [ 16 , 17 ]. With the AC–DC input stage, there is the possibility of the implementing power factor correction [ 16 , 17 , 18 , 19 , 20 , 21 , 22 ].…”
Section: Introductionmentioning
confidence: 99%