2006
DOI: 10.1039/b516767a
|View full text |Cite
|
Sign up to set email alerts
|

A high accuracy primary ratio method for the determination of iodine in complex matrices by double isotope dilution using MC-ICPMS and 129I spike

Abstract: Iodine is an essential element and yet is poorly represented in matrix reference materials. In this paper a novel development of the double IDMS equation using 129 I spike is presented which is ideally suited for the provision of primary measurements of iodine in complex matrices. Tolerances of the double IDMS method for iodine determination using a multi-collector ICPMS have been explored. The results indicate that even early approximates of the iodine concentration in the sample will give accurate results. T… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
33
0

Year Published

2007
2007
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 23 publications
(33 citation statements)
references
References 22 publications
0
33
0
Order By: Relevance
“…An aliquot of 0·5 g was mixed with 5 ml of 5 % tetramethylammonium hydroxide (TMAH) solution, prepared by dissolving solid TMAH ( ≥ 97 %; Sigma Aldrich, Gillingham, Dorset, UK) in ultrapure water. The vial was then placed in an oven at 90°C for 3 h ( 23 ) . To each sample, 0·5 ml of the internal standard was added (1300 ng/ml tellurium in 1 % TMAH; Romil, Cambridge, UK) and the samples were made up to 50 g with 1 % TMAHsolution.…”
Section: Methodsmentioning
confidence: 99%
“…An aliquot of 0·5 g was mixed with 5 ml of 5 % tetramethylammonium hydroxide (TMAH) solution, prepared by dissolving solid TMAH ( ≥ 97 %; Sigma Aldrich, Gillingham, Dorset, UK) in ultrapure water. The vial was then placed in an oven at 90°C for 3 h ( 23 ) . To each sample, 0·5 ml of the internal standard was added (1300 ng/ml tellurium in 1 % TMAH; Romil, Cambridge, UK) and the samples were made up to 50 g with 1 % TMAHsolution.…”
Section: Methodsmentioning
confidence: 99%
“…Sample preparation and analysis were performed using a method previously validated in-house against a primary reference method, namely isotope dilution mass spectrometry(28). In brief, the samples were first digested by mixing 0.5 g liquid (weighed to four decimal places) in a glass vial with 5 ml of 5% tetramethylammonium hydroxide (TMAH), prepared using solid TMAH (≥97%; Sigma Aldrich, Gillingham, Dorset, UK) dissolved in ultrapure water (18.2 MΩ cm, Elga PureFlex, UK).…”
Section: Methodsmentioning
confidence: 99%
“…The most common of the traditional methods is colorimetry based on the Sandell-Kolthoff reaction, in which iodide catalyzes the reduction of ceric ammonium sulfate by arsenious acid (15)(16)(17)(18). The emergence of newer instrumental methods based on coupled ion chromatography and inductively coupled plasma mass spectrometry (ICP-MS) permit measurements of greater specificity and sensitivity, although at higher cost (19)(20)(21)(22).…”
Section: Srms For Urinary Iodinementioning
confidence: 99%